12.3.3 装置の状態確認
- 〈この項の構成〉
(1) 運用状態の確認
運用コマンドshow systemで次の情報を確認できます。
-
装置の情報
-
ファン,電源機構,および各ボード(BCU/SFU/PSU/NIF)の情報
次の図に例を示します。
> show system
Date 20XX/04/01 01:52:01 UTC
System: AX8616S, OS-SE, Ver.12.6, [9896.21]
Elapsed time: 2 days 04:30
Name: System
Contact: Contact
Location: Location
Chassis MAC address: 0012.e286.5300
BCU redundancy status: duplex
FAN control mode: 1 (normal)
Temperature warning level: current = 45, average = 45
High temperature action: stop
Power redundancy mode: 2 (Power Supply + Input Source)
Hardware profile
Configuration: switch-1
Current: switch-1
Failure action (software): unicast switchover
multicast switchover
System MTU: 1518
Hardware information
FAN1: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
FAN2: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
FAN3: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
FAN4: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
FAN5: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
FAN6: active
Elapsed time: 2 days 04:30
Lamp: STATUS LED = green
PS1: active
Elapsed time: 2 days 04:30
PS2: active
Elapsed time: 2 days 04:30
PS3: active
Elapsed time: 2 days 04:30
PS4: active
Elapsed time: 2 days 04:30
BCU1: active
Elapsed time: 2 days 04:30
Boot device: primary
BCU-CPU: active
Boot: 20XX/03/29 09:10:46 UTC, power on, fatal error restart 0 time
Board: clock 2.0GHz, memory 8,034,106KB
PA: active
Boot: 20XX/03/29 09:10:46 UTC, power on, fatal error restart 0 time
Board: clock 1.1GHz, memory 2,097,152KB
Lamp: STATUS LED = green, ACTIVE LED = green
SYSTEM1 LED = green, SYSTEM2 LED = light off
System operation panel: no error
Management port: active up
10BASE-T half(auto), 0012.e286.5301
Temperature: normal (32 degree C)
Flash: enabled, 6,153,286KB
MC: notconnect
BCU2: standby
Elapsed time: 2 days 04:30
Boot device: primary
BCU-CPU: active
Boot: 20XX/03/29 09:10:53 UTC, power on, fatal error restart 0 time
Board: clock 2.0GHz, memory 8,034,106KB
PA: active
Boot: 20XX/03/29 09:10:53 UTC, power on, fatal error restart 0 time
Board: clock 1.1GHz, memory 2,097,152KB
Lamp: STATUS LED = green, ACTIVE LED = green
SYSTEM1 LED = green, SYSTEM2 LED = light off
System operation panel: no error
Management port: unused
-, -
Temperature: normal (32 degree C)
Flash: enabled, 6,153,286KB
MC: notconnect
SFU1: active, fatal error restart 0 time
Elapsed time: 2 days 04:34
Lamp: STATUS LED = green, ACTIVE LED = green
SFU2: notconnect
SFU3: notconnect
SFU4: notconnect
PSU1: active, fatal error restart 0 time
Elapsed time: 2 days 04:30
Boot: 20XX/03/29 09:20:26 UTC
Board: clock 0.8GHz, memory 3,760,820KB
Lamp: STATUS LED = green
Forwarding database management
Forwarding-table allocation
Configuration: default
Current: default
Flow database management
Flow-table allocation
Configuration: default
Current: default
Flow detection mode
Configuration: quantity-oriented
Current: quantity-oriented
PSU2: notconnect
PSU3: notconnect
PSU4: notconnect
NIF1: active, fatal error restart 0 time
Elapsed time: 2 days 04:34
Lamp: STATUS LED = green
NIF2: notconnect
:
NIF16: notconnect
> |
(2) 環境状態の確認
運用コマンドshow environmentで次の情報を確認できます。
-
ファンの情報
-
電源機構の情報
-
電力使用情報
-
BCUの入気温度
-
各ボード(BCU/SFU/PSU/NIF)の温度状態
-
各ボード(BCU/SFU/PSU/NIF)の稼働時間情報
次の図に例を示します。
> show environment
Date 20XX/03/27 06:16:38 UTC
FAN environment
FAN1: active, Speed = 2600
FAN2: active, Speed = 2600
FAN3: fault
FAN4: active, Speed = 2600
FAN5: active, Speed = 2600
FAN6: active, Speed = high
Mode: 1 (normal)
Power environment
Input voltage: AC200-240V
Power redundancy mode: 2 (Power Supply + Input Source)
Power supply redundancy status
Power supply: active = 4, required = 1 (Redundant)
Input source: active = 2(from A) 2(from B), required = 1 (Redundant)
PS1: active
PS2: active
PS3: active
PS4: active
Power usage
Total power capacity: 10168.00 W
Input source A: 5084.00 W
Input source B: 5084.00 W
Total power allocated: 1477.00 W
Total power available for additional boards: 8691.00 W
Power available (Power supply unit redundant case): 6149.00 W
Power available (Input source redundant case)
Input source A: 3607.00 W
Input source B: 3607.00 W
Inlet temperature
BCU1: normal (36 degree C)
BCU2: normal (36 degree C)
Board temperature
BCU1: normal
BCU2: normal
SFU1: normal
SFU2: notconnect
SFU3: notconnect
SFU4: notconnect
PSU1: normal
PSU2: notconnect
PSU3: notconnect
PSU4: notconnect
NIF1: normal
NIF2: notconnect
:
NIF16: notconnect
Accumulated running time
total caution critical
BCU1 2 days 16 hours 1 day 1 hour 0 days 0 hours
BCU2 2 days 16 hours 1 day 1 hour 0 days 0 hours
SFU1 2 days 16 hours 1 day 1 hour 0 days 0 hours
SFU2 notconnect
SFU3 notconnect
SFU4 notconnect
PSU1 2 days 16 hours 1 day 1 hour 0 days 0 hours
PSU2 notconnect
PSU3 notconnect
PSU4 notconnect
NIF1 2 days 16 hours 1 day 1 hour 0 days 0 hours
NIF2 notconnect
:
NIF16 notconnect
PS1 2 days 16 hours 1 day 1 hour 0 days 0 hours
PS2 2 days 16 hours 1 day 1 hour 0 days 0 hours
PS3 2 days 16 hours 1 day 1 hour 0 days 0 hours
PS4 2 days 16 hours 1 day 1 hour 0 days 0 hours
FAN1 2 days 16 hours 1 day 1 hour 0 days 0 hours
FAN2 2 days 16 hours 1 day 1 hour 0 days 0 hours
:
FAN6 2 days 16 hours 1 day 1 hour 0 days 0 hours
> |
(3) 温度履歴情報の確認
運用コマンドshow environmentのtemperature-loggingパラメータで入気温度履歴情報を最大で2年分確認できます。temperature-loggingパラメータを指定すると,6時間ごとに記録した平均入気温度を表示します。次の図に例を示します。
> show environment temperature-logging Date 20XX/04/01 01:44:40 UTC BCU1 Date 0:00 6:00 12:00 18:00 20XX/04/01 32.9 20XX/03/31 33.0 33.0 33.0 33.0 20XX/03/30 33.0 33.0 33.0 33.0 20XX/03/29 - - 33.7 33.0 BCU2 Date 0:00 6:00 12:00 18:00 20XX/04/01 32.9 20XX/03/31 33.0 33.0 33.0 33.0 20XX/03/30 33.0 33.0 33.0 33.0 20XX/03/29 - - 33.7 33.0 > |