コンフィグレーションガイド Vol.1


12.3.3 装置の状態確認

〈この項の構成〉

(1) 運用状態の確認

運用コマンドshow systemで次の情報を確認できます。

次の図に例を示します。

図12‒39 運用状態の確認
> show system
Date 20XX/04/01 01:52:01 UTC
System: AX8616S, OS-SE, Ver.12.6, [9896.21]
    Elapsed time: 2 days 04:30
    Name: System
    Contact: Contact
    Location: Location
    Chassis MAC address: 0012.e286.5300
    BCU redundancy status: duplex
    FAN control mode: 1 (normal)
    Temperature warning level: current = 45, average = 45
    High temperature action: stop
    Power redundancy mode: 2 (Power Supply + Input Source)
    Hardware profile
        Configuration: switch-1
        Current: switch-1
    Failure action (software): unicast switchover
                               multicast switchover
    System MTU: 1518
 
Hardware information
    FAN1: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    FAN2: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    FAN3: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    FAN4: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    FAN5: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    FAN6: active
        Elapsed time: 2 days 04:30
        Lamp: STATUS LED = green
    PS1: active
        Elapsed time: 2 days 04:30
    PS2: active
        Elapsed time: 2 days 04:30
    PS3: active
        Elapsed time: 2 days 04:30
    PS4: active
        Elapsed time: 2 days 04:30
    BCU1: active
        Elapsed time: 2 days 04:30
        Boot device: primary
        BCU-CPU: active
            Boot: 20XX/03/29 09:10:46 UTC, power on, fatal error restart 0 time
            Board: clock 2.0GHz, memory 8,034,106KB
        PA: active
            Boot: 20XX/03/29 09:10:46 UTC, power on, fatal error restart 0 time
            Board: clock 1.1GHz, memory 2,097,152KB
        Lamp: STATUS LED = green, ACTIVE LED = green
              SYSTEM1 LED = green, SYSTEM2 LED = light off
        System operation panel: no error
        Management port: active up
            10BASE-T half(auto), 0012.e286.5301
        Temperature: normal (32 degree C)
        Flash: enabled, 6,153,286KB
        MC: notconnect
    BCU2: standby
        Elapsed time: 2 days 04:30
        Boot device: primary
        BCU-CPU: active
            Boot: 20XX/03/29 09:10:53 UTC, power on, fatal error restart 0 time
            Board: clock 2.0GHz, memory 8,034,106KB
        PA: active
            Boot: 20XX/03/29 09:10:53 UTC, power on, fatal error restart 0 time
            Board: clock 1.1GHz, memory 2,097,152KB
        Lamp: STATUS LED = green, ACTIVE LED = green
              SYSTEM1 LED = green, SYSTEM2 LED = light off
        System operation panel: no error
        Management port: unused
            -, -
        Temperature: normal (32 degree C)
        Flash: enabled, 6,153,286KB
        MC: notconnect
    SFU1: active, fatal error restart 0 time
        Elapsed time: 2 days 04:34
        Lamp: STATUS LED = green, ACTIVE LED = green
    SFU2: notconnect
    SFU3: notconnect
    SFU4: notconnect
    PSU1: active, fatal error restart 0 time
        Elapsed time: 2 days 04:30
        Boot: 20XX/03/29 09:20:26 UTC
        Board: clock 0.8GHz, memory 3,760,820KB
        Lamp: STATUS LED = green
        Forwarding database management
            Forwarding-table allocation
                Configuration: default
                Current: default
        Flow database management
            Flow-table allocation
                Configuration: default
                Current: default
            Flow detection mode
                Configuration: quantity-oriented
                Current: quantity-oriented
    PSU2: notconnect
    PSU3: notconnect
    PSU4: notconnect
    NIF1: active, fatal error restart 0 time
        Elapsed time: 2 days 04:34
        Lamp: STATUS LED = green
    NIF2: notconnect
     :
    NIF16: notconnect
>

(2) 環境状態の確認

運用コマンドshow environmentで次の情報を確認できます。

次の図に例を示します。

図12‒40 環境状態の確認
> show environment
Date 20XX/03/27 06:16:38 UTC
 
FAN environment
    FAN1: active, Speed = 2600
    FAN2: active, Speed = 2600
    FAN3: fault
    FAN4: active, Speed = 2600
    FAN5: active, Speed = 2600
    FAN6: active, Speed = high
    Mode: 1 (normal)
 
Power environment
    Input voltage: AC200-240V
    Power redundancy mode: 2 (Power Supply + Input Source)
    Power supply redundancy status
        Power supply: active = 4, required = 1 (Redundant)
        Input source: active = 2(from A) 2(from B), required = 1 (Redundant)
    PS1: active
    PS2: active
    PS3: active
    PS4: active
 
Power usage
    Total power capacity:                                10168.00 W
        Input source A:                                   5084.00 W
        Input source B:                                   5084.00 W
    Total power allocated:                                1477.00 W
    Total power available for additional boards:          8691.00 W
    Power available (Power supply unit redundant case):   6149.00 W
    Power available (Input source redundant case)
        Input source A:                                   3607.00 W
        Input source B:                                   3607.00 W
 
Inlet temperature
    BCU1: normal (36 degree C)
    BCU2: normal (36 degree C)
 
Board temperature
    BCU1: normal
    BCU2: normal
    SFU1: normal
    SFU2: notconnect
    SFU3: notconnect
    SFU4: notconnect
    PSU1: normal
    PSU2: notconnect
    PSU3: notconnect
    PSU4: notconnect
    NIF1: normal
    NIF2: notconnect
     :
    NIF16: notconnect
 
Accumulated running time
                 total               caution             critical
    BCU1       2 days 16 hours      1 day   1 hour       0 days   0 hours
    BCU2       2 days 16 hours      1 day   1 hour       0 days   0 hours
    SFU1       2 days 16 hours      1 day   1 hour       0 days   0 hours
    SFU2    notconnect
    SFU3    notconnect
    SFU4    notconnect
    PSU1       2 days 16 hours      1 day   1 hour       0 days   0 hours
    PSU2    notconnect
    PSU3    notconnect
    PSU4    notconnect
    NIF1       2 days 16 hours      1 day   1 hour       0 days   0 hours
    NIF2    notconnect
     :
    NIF16   notconnect
    PS1        2 days 16 hours      1 day   1 hour       0 days   0 hours
    PS2        2 days 16 hours      1 day   1 hour       0 days   0 hours
    PS3        2 days 16 hours      1 day   1 hour       0 days   0 hours
    PS4        2 days 16 hours      1 day   1 hour       0 days   0 hours
    FAN1       2 days 16 hours      1 day   1 hour       0 days   0 hours
    FAN2       2 days 16 hours      1 day   1 hour       0 days   0 hours
     :
    FAN6       2 days 16 hours      1 day   1 hour       0 days   0 hours
>

(3) 温度履歴情報の確認

運用コマンドshow environmentのtemperature-loggingパラメータで入気温度履歴情報を最大で2年分確認できます。temperature-loggingパラメータを指定すると,6時間ごとに記録した平均入気温度を表示します。次の図に例を示します。

図12‒41 温度履歴情報の確認
> show environment temperature-logging
Date 20XX/04/01 01:44:40 UTC
BCU1
Date         0:00  6:00 12:00 18:00
20XX/04/01   32.9
20XX/03/31   33.0  33.0  33.0  33.0
20XX/03/30   33.0  33.0  33.0  33.0
20XX/03/29      -     -  33.7  33.0
 
BCU2
Date         0:00  6:00 12:00 18:00
20XX/04/01   32.9
20XX/03/31   33.0  33.0  33.0  33.0
20XX/03/30   33.0  33.0  33.0  33.0
20XX/03/29      -     -  33.7  33.0
>