2.10 POE
This section describes the operation messages for the event location POE.
Message ID |
Event Level |
Message text |
---|---|---|
Content and response |
||
39000001 |
E3 |
Initialization PoE configuration. |
Configure PoE settings. [Action] None. |
||
39000003 |
E3 |
<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the overload detection. |
Power supply was stopped because an overload was detected. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Check the devices receiving the power. If devices to which PoE power can be supplied are connected, use the power inline configuration command to disable PoE on the target port. |
||
39000004 |
E3 |
<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the thermal shutdown. |
Power was stopped because a thermal error was detected in PoE controllers. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Review the installation environment of the equipment and reconnect. |
||
39000005 |
E3 |
<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the PD disorder.(xxxx) |
Power supply was stopped because a failure of the power receiving device was detected. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number (xxxx) Power supply stop factor [Action] Execute activate power inline commandPlease do. If it does not recover, check the power receiving device or cable, and connect again. |
||
39000006 |
E3 |
<switch no.>/<nif no.>/<port no.> Unable to supply power by the power shortage. |
Power cannot be supplied due to a power shortage of the entire equipment. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] If you want to power this port, use show power inline commandto check Threshold and Allocate, and reduce the number of connected powered devices so that Allocate is below Threshold. Alternatively, use the configuration command power inline to change the priorities. Review the settings, and then execute activate power inline commandPlease. |
||
39000009 |
E8 |
Init controller failed. |
Failed to set PoE configuration. [Action] None. The appliance automatically restarts. |
||
3900000a |
E8 |
PoE controller access failed.(xxxx) |
Accessing PoE controllerfailed. (xxxx) Cause code (manufacturer analysis information) [Action] None. The appliance automatically restarts. |
||
3900000c |
E8 |
<ps>: Unsupported PSU can not supply power. |