Message and Log Reference


2.4.2 01XXXXXX

This section describes operation messages in which the two most significant digits of the message identifier are 01.

Table 2-5: Operation messages for event location SOFTWARE (01XXXXXX)

Message

ID

Event

Level

Message text

Content and response

01100001

01100002

01100004

01200001

01200002

01200004

01300001

01300002

01300004

01400001

01400002

01400004

01600001

01600002

01600004

01700001

01700002

01700004

01800001

01800002

01800004

01900001

01900002

01900004

01910001

01910002

01910004

E7

Software failure occurred during operation.

An error occurred in the software during operation.

[Action]

Normal operation might not be possible. Take the following actions:

  1. Check the log by executing the show logging command. If another problem is indicated in the log, take appropriate action according to the error message.

  2. Use the reload command to restart the device.

  3. After you use the reload command to restart the system, if the same problem occurs, replace the device.

01100003

01200003

01300003

01400003

01600003

01700003

01800003

01900003

01910003

E9

System will restart due to software failure occurred during initialization.

The Switch restarts because a software failure occurred during initialization.

[Action]

Check the log by executing the show logging command. If another problem is indicated in the log, take appropriate action according to the error message.

01100005

01200005

01300005

01400005

01600005

01700005

01800005

01900005

01910005

E9

System will restart due to software failure occurred during operation.

The Switch is restarted because a software error occurred during operation.

[Action]

Check the log by executing the show logging command. If another problem is indicated in the log, take appropriate action according to the error message.

01200187

E3

The temperature logging file can't be written.

Writing of temperature logging information failed.

[Action]

  1. Check the user area of the internal flash memory.

  2. If there is insufficient free space, remove unnecessary files and secure the free space (approximately 8KB).

01200213

E7

The CPU memory is insufficient.

There is not enough CPU memory.

[Action]

  1. If many users are logged in, log out all but the most essential users.

  2. If there is a lot of use from ftp, disconnect all but the most essential connections.

  3. If there is too much access from the network management device, limit the amount of access to the minimum necessary.

  4. If the above conditions 1, 2, and 3 do not recover, the capacity conditions of the Switch may not be satisfied. Review the network configuration by referring to Vol.1" "3 Capacity Limits in the Configuration Guide.

R7

The CPU has recovered from insufficient memory.

The CPU has recovered from a lack of memory.

[Action]

None.

01200220

E9

System will restart due to WDT timeout.

The device restarts. because of a WDT (watchdog timer) timeout.

[Action]

After the Switch is restarted, use show logging command to check the log. If another error has occurred, take the appropriate action.

01700501

E3

Statistics table initialized.

A statistical table that holds CPU usage was initialized because the time on the device was changed by set clock commandI will.

[Action]

None.

01700502

E3

CPU overloaded. There is the possibility of software failure in responding to user command input or sending notification to SNMP agent.

The response to a user-entered command might have failed or a notification to an SNMP agent might have failed. The CPU might be overloaded.

[Action]

If necessary, reenter command or retrieve MIB.

01700503

E3

There is the possibility of software failure in responding to user command input or sending notification to SNMP agent.

The response to a user-entered command might have failed or a notification to an SNMP agent might have failed.

[Action]

If necessary, reenter command or retrieve MIB.

01900250

E3

Software started up.

The software has started.

This log data is collected in UTC time.

[Action]

None.

01910201

E3

System started collecting new "error.log".

The system has started collecting data into a new reference log.

[Action]

None.

01910202

E3

System restarted by user operation.

The system was restarted by a user operation.

[Action]