13.1.4 Operation in case of failure
The following tables show the operation when a MC failure is detected while MC operation is enabled.
Event trigger |
Cause of the failure |
Operation |
---|---|---|
When the Switch starts up |
MC not incorporated |
The unit starts up with the software and device information of the internal flash memory. In addition, an operation log indicating that reading of the data in MC failed is collected. |
MC read fail |
||
When inserting MC |
MC write fail |
An operation log indicating that MC failed is collected. Also, ST2 LED lights in orange*1. |
Insufficient MC space |
||
When MC command*2 is executed |
MC not incorporated |
A response message is displayed indicating a command execution error. |
MC write fail |
||
Insufficient MC space |
||
Command other than the above*3 execution |
MC not incorporated |
An operation log indicating that MC failed is collected. |
MC write fail |
||
Insufficient MC space |