2.12 ULR
This section describes the operation messages for the event location ULR.
Message ID |
Event Level |
Message text |
---|---|---|
Content and response |
||
20a00001 |
E4 |
ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(<switch no.>/<nif no.>/<port no.>). |
The active port was switched to the secondary port because an error occurred in the primary port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Check the failure in the primary port. |
||
20a00002 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>). |
The active port was switched to the primary port because an error occurred in the secondary port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Check the failure in the secondary port. |
||
20a00003 |
E4 |
ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(ChGr:<channel group number>). |
The active port was switched to the secondary port because an error occurred in the primary port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] Check the failure in the primary port. |
||
20a00004 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>). |
The active port was switched to the primary port because an error occurred in the secondary port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] Check the failure in the secondary port. |
||
20a00005 |
E4 |
ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(<switch no.>/<nif no.>/<port no.>). |
The active port was switched to the secondary port because an error occurred in the primary port. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Check the failure in the primary port. |
||
20a00006 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>). |
The active port was switched to the primary port because an error occurred in the secondary port. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Check the failure in the secondary port. |
||
20a00007 |
E4 |
ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(ChGr:<channel group number>). |
The active port was switched to the secondary port because an error occurred in the primary port. <channel group number>: Channel group number [Action] Check the failure in the primary port. |
||
20a00008 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(ChGr:<channel group number>). |
The active port was switched to the primary port because an error occurred in the secondary port. <channel group number>: Channel group number [Action] Check the failure in the secondary port. |
||
20a00009 |
E4 |
ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(<switch no.>/<nif no.>/<port no.>), because command execution. |
The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00010 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>), because command execution. |
The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00011 |
E4 |
ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(ChGr:<channel group number>), because command execution. |
The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] None. |
||
20a00012 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>), because command execution. |
The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] None. |
||
20a00013 |
E4 |
ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(<switch no.>/<nif no.>/<port no.>), because command execution. |
The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00014 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>), because command execution. |
The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00015 |
E4 |
ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(ChGr:<channel group number>), because command execution. |
The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed. <channel group number>: Channel group number [Action] None. |
||
20a00016 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(ChGr:<channel group number>), because command execution. |
The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed. <channel group number>: Channel group number [Action] None. |
||
20a00017 |
E4 |
ULR:Primary port(<switch no.>/<nif no.>/<port no.>) became the active port. |
The primary port has become the active port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00018 |
E4 |
ULR:Primary port(ChGr:<channel group number>), became the active port. |
The primary port has become the active port. <channel group number>: Channel group number [Action] None. |
||
20a00019 |
E4 |
ULR:Secondary port(<switch no.>/<nif no.>/<port no.>) became the active port. |
The secondary port has become the active port. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00020 |
E4 |
ULR:Secondary port(ChGr:<channel group number>) became the active port. |
The secondary port has become the active port. <channel group number>: Channel group number [Action] None. |
||
20a00021 |
E4 |
ULR:Both uplink redundant port(<switch no.>/<nif no.>/<port no.>) and port(<switch no.>/<nif no.>/<port no.>) are down. |
Both the primary port and the secondary port have gone down. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Make sure that no error occurred between the primary and secondary port. |
||
20a00022 |
E4 |
ULR:Both uplink redundant port(<switch no.>/<nif no.>/<port no.>) and port(ChGr:<channel group number>) are down. |
Both the primary port and the secondary port have gone down. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] Make sure that no error occurred between the primary and secondary port. |
||
20a00023 |
E4 |
ULR:Both uplink redundant port(ChGr:<channel group number>) and port(<switch no.>/<nif no.>/<port no.>) are down. |
Both the primary port and the secondary port have gone down. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] Make sure that no error occurred between the primary and secondary port. |
||
20a00024 |
E4 |
ULR:Both uplink redundant port(ChGr:<channel group number>) and port(ChGr:<channel group number>) are down. |
Both the primary port and the secondary port have gone down. <channel group number>: Channel group number [Action] Make sure that no error occurred between the primary and secondary port. |
||
20a00025 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>), because preemption execution. |
The active port was switched from the secondary port to the primary port because automatic preemption was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00026 |
E4 |
ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>), because preemption execution. |
The active port was switched from the secondary port to the primary port because automatic preemption was executed. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number <channel group number>: Channel group number [Action] None. |
||
20a00027 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>), because preemption execution. |
The active port was switched from the secondary port to the primary port because automatic preemption was executed. <channel group number>: Channel group number <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00028 |
E4 |
ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(ChGr:<channel group number>), because preemption execution. |
The active port was switched from the secondary port to the primary port because automatic preemption was executed. <channel group number>: Channel group number [Action] None. |
||
20a00029 |
E4 |
ULR:Exceeded the number of MAC Address Table entry update request to uplink-switch from active port(<switch no.>/<nif no.>/<port no.>). |
The number of MAC address table entry update requests from an uplink port of the Switch to an upstream uplink switch exceeded the limit. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00030 |
E4 |
ULR:Exceeded the number of MAC Address Table entry update request to uplink-switch from active port(ChGr:<channel group number>). |
The number of MAC address table entry update requests from an uplink port of the Switch to an upstream uplink switch exceeded the limit. <channel group number>: Channel group number [Action] None. |
||
20a00031 |
E4 |
ULR:Port(<switch no.>/<nif no.>/<port no.>) inactivated because of 'reset-flush-port'. |
The port is placed in inactive status by the port reset function. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00032 |
E4 |
ULR:ChGr(<channel group number>) inactivated because of 'reset-flush-port'. |
The port is placed in inactive status by the port reset function. <channel group number>: Channel group number [Action] None. |
||
20a00033 |
E4 |
ULR:Port(<switch no.>/<nif no.>/<port no.>) activated because of 'reset-flush-port'. |
The port is released from inactive status by the port reset function. <switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number [Action] None. |
||
20a00034 |
E4 |
ULR:ChGr(<channel group number>) activated because of 'reset-flush-port'. |
The port is released from inactive status by the port reset function. <channel group number>: Channel group number [Action] None. |