2.1 EQUIPMENT
This section describes the operation messages for the event location EQUIPMENT.
Message ID |
Event Level |
Message text |
---|---|---|
Content and response |
||
00000003 |
E3 |
Failed in accumulated running time access to main. |
Access to the total operating time for the switch failed. [Action] This event does not affect communication and usual operation. However, you cannot use the total operating time management function. If you want to use this function, replace the device. |
||
0000011f |
E5 |
An access error was detected on the internal flash memory. |
An access error to the internal flash memory was detected. [Action] Replace the internal flash memory because it may be damaged. |
||
00020102 |
E7 |
Hardware exceeded tolerance level of low temperature(<temperature> degree). Check room temperature. |
The hardware temperature went below the permissible temperature range (<temperature> degrees Celsius or lower). <temperature> -10 [Action]
|
||
R7 |
The temperature of hardware returned to normal level (<temperature> degree). |
|
The hardware temperature returned to normal (<temperature> degrees Celsius). <temperature> -7 [Action] None. |
||
00020103 |
E7 |
Hardware exceeded tolerance level of high temperature (<temperature> degree). Check that room temperature and the fan is operating normally. |
The hardware temperature rose above the permissible temperature range (<temperature> degrees Celsius or higher). <temperature> 50 (with fixed power supply or FAN-04) <temperature> 40(FAN-04R is installed.) [Action]
|
||
R7 |
The temperature of hardware returned to normal level (<temperature> degree). |
|
The hardware temperature returned to normal (<temperature> degrees Celsius). <temperature> 47 (with fixed power supply or FAN-04) <temperature> 37(FAN-04R is installed.) [Action] None. |
||
00020105 |
E9 |
Hardware is becoming high temperature which give damage to this system (<temperature> degree). |
The hardware temperature has reached a temperature (<temperature> degrees Celsius or higher) that is likely to critically damage device operation. <temperature> Detected temp. over 60°C (with fixed power supply or FAN-04) <temperature> Detected temperature (50°C or more) (when FAN-04R is installed) [Action]
|
||
00020106 |
E3 |
The temperature of hardware reached the warning level (<temperature> degree). |
The hardware has reached the temperature that is set with the system temperature-warning-level configuration command. <temperature>: Intake air temperature of the device (in Celsius). [Action] The temperature of the device has reached the specified temperature. Check the environment surrounding the device (condition of the fan, ventilation, existence of the heat sources, etc.). |
||
00020107 |
E3 |
The temperature of hardware came down from the warning level. |
The hardware temperature has been 3 degrees Celsius or more lower than the temperature that is set with the system temperature-warning-level configuration command. [Action] None. |
||
25000110 |
E8 |
Switching unit stopped because its hardware failure detected during the self diagnosis. |
A fault was detected during hardware self-test. [Action] Replace the Switch. |
||
25040200 |
R8 |
Hardware initialized. |
The hardware has been initialized. [Action] None. |
||
25040201 |
E8 |
Hardware restarted because of its failure. |
The switch was restarted because a hardware failure occurred at the switch. [Action] Check subsequent fault recovery log entries or fault recovery failure log entries. If the recovery was successful, operations can resume. If the recovery failed, replace the device. |
||
R8 |
Hardware recovered. |
|
The switch recovered from a hardware failure. [Action] None. |
||
25040400 |
E8 |
Hardware restarted, but not recovered. |
The device restarted, but it has not recovered from a hardware failure. [Action] Replace the Switch. |
||
25040c01 |
E3 |
Corrected memory soft errors. |
The system has recovered from a memory software error. Some frames may be discarded because of the software error. [Action] None. This indicates that the memory data bits inside a switch processor might have been abruptly altered (for example by cosmic rays from a solar flare) and a software error is issued temporarily. This is not a hardware failure. |
||
250a0210 |
E3 |
Synchronous Ethernet with internal clock was selected. |
Operation by the internal clock has started. [Action] None. |