Message and Log Reference


2.1 EQUIPMENT

This section describes the operation messages for the event location EQUIPMENT.

Table 2-1: Operation messages for event location EQUIPMENT

Message

ID

Event

Level

Message text

Content and response

00000003

E3

Failed in accumulated running time access to main.

Access to the total operating time for the switch failed.

[Action]

This event does not affect communication and usual operation. However, you cannot use the total operating time management function. If you want to use this function, replace the device.

0000011f

E5

An access error was detected on the internal flash memory.

An access error to the internal flash memory was detected.

[Action]

Replace the internal flash memory because it may be damaged.

00020102

E7

Hardware exceeded tolerance level of low temperature(<temperature> degree). Check room temperature.

The hardware temperature went below the permissible temperature range (<temperature> degrees Celsius or lower).

<temperature> -10

[Action]

  1. Check and, if necessary, improve the environment such as the room temperature around the switches.

  2. Check and, if necessary, replace the fan.

R7

The temperature of hardware returned to normal level (<temperature> degree).

The hardware temperature returned to normal (<temperature> degrees Celsius).

<temperature> -7

[Action]

None.

00020103

E7

Hardware exceeded tolerance level of high temperature (<temperature> degree). Check that room temperature and the fan is operating normally.

The hardware temperature rose above the permissible temperature range (<temperature> degrees Celsius or higher).

<temperature> 50 (with fixed power supply or FAN-04)

<temperature> 40(FAN-04R is installed.)

[Action]

  1. Check and improve the environment such as ventilation and heat sources around the switches.

  2. Check and, if necessary, replace the fan.

R7

The temperature of hardware returned to normal level (<temperature> degree).

The hardware temperature returned to normal (<temperature> degrees Celsius).

<temperature> 47 (with fixed power supply or FAN-04)

<temperature> 37(FAN-04R is installed.)

[Action]

None.

00020105

E9

Hardware is becoming high temperature which give damage to this system (<temperature> degree).

The hardware temperature has reached a temperature (<temperature> degrees Celsius or higher) that is likely to critically damage device operation.

<temperature> Detected temp. over 60°C (with fixed power supply or FAN-04)

<temperature> Detected temperature (50°C or more) (when FAN-04R is installed)

[Action]

  1. Check and improve the environment such as ventilation and heat sources around the switches.

  2. Check and, if necessary, replace the fan.

00020106

E3

The temperature of hardware reached the warning level (<temperature> degree).

The hardware has reached the temperature that is set with the system temperature-warning-level configuration command.

<temperature>: Intake air temperature of the device (in Celsius).

[Action]

The temperature of the device has reached the specified temperature. Check the environment surrounding the device (condition of the fan, ventilation, existence of the heat sources, etc.).

00020107

E3

The temperature of hardware came down from the warning level.

The hardware temperature has been 3 degrees Celsius or more lower than the temperature that is set with the system temperature-warning-level configuration command.

[Action]

None.

25000110

E8

Switching unit stopped because its hardware failure detected during the self diagnosis.

A fault was detected during hardware self-test.

[Action]

Replace the Switch.

25040200

R8

Hardware initialized.

The hardware has been initialized.

[Action]

None.

25040201

E8

Hardware restarted because of its failure.

The switch was restarted because a hardware failure occurred at the switch.

[Action]

Check subsequent fault recovery log entries or fault recovery failure log entries. If the recovery was successful, operations can resume.

If the recovery failed, replace the device.

R8

Hardware recovered.

The switch recovered from a hardware failure.

[Action]

None.

25040400

E8

Hardware restarted, but not recovered.

The device restarted, but it has not recovered from a hardware failure.

[Action]

Replace the Switch.

25040c01

E3

Corrected memory soft errors.

The system has recovered from a memory software error. Some frames may be discarded because of the software error.

[Action]

None.

This indicates that the memory data bits inside a switch processor might have been abruptly altered (for example by cosmic rays from a solar flare) and a software error is issued temporarily. This is not a hardware failure.

250a0210

E3

Synchronous Ethernet with internal clock was selected.

Operation by the internal clock has started.

[Action]

None.