Configuration Guide Vol. 1


14.1.3 Checking the status of the switch status

You can use the operation-command show system to check the operating status of the switch and the amount of mounted memories. An example is shown below:

Figure 14-2: Checking the status of the switch
> show system
Date 20XX/01/16 17:53:12 UTC
System: AX3660S-48XT4QW, OS-L3M (SL-L3A-001) Ver. 12.1.D
Node : Name=
    Contact=
    Locate=
    Elapsed time : 00:45:03
    LED Brightness mode : normal
    Machine ID : 0012.e23e.b20f
    Power redundancy-mode : check is not executed
    Power slot 1 : active PS-M(AC)
        Fan  : active No = Fan1(1)  Speed = --------, Direction = F-to-R
        PS   : active
    Power slot 2 : notconnect
    Fan slot : active FAN-M
        Fan  : active No = Fan3(1) , Fan3(2) , Fan3(3) , Fan3(4)
               Speed = normal , Direction = F-to-R
        Lamp : ALM LED=light off
    Main board : active
        Boot : 20XX/01/16 17:08:19 , operation reboot
        Fatal restart : CPU 0 times ,  SW 0 times
        Lamp : Power LED=green , Status LED1=green
        Board : CPU=AMD GX-420 2000MHz , Memory=4,194,304KB(4096MB)
        Management port: active up
             100BASE-TX full(auto) 0012.e23e.b20f
        Temperature : normal(26degree)
        Flash :
                  user area   config area     dump area    area total
            used  238,599KB          99KB           0KB     238,698KB 
            free  229,857KB     116,963KB     131,008KB     477,828KB 
            total 468,456KB     117,062KB     131,008KB     716,526KB
        MC  : enabled
            Manufacture ID : 00000030
            24,077KB used
            971,008KB free
            995,085KB total
        System interface hundredgigabitethernet : 
            disable (10G)  : 0/21-22,37-44
            enable  (100G) : 0/49,51-52
    Device resources
        Current selected swrt_table_resource : l3switch-2
        Current selected swrt_multicast_table : Off
        Current selected unicast multipath number: 4
        Current selected port-channel load-balance-all-port: Off
        IP routing entry :
            Unicast : current number=98 , max number=8093
            Multicast : current number=0 , max number=2048
            ARP : current number=2 , max number=15360
        IPv6 routing entry :
            Unicast : current number=34 , max number=3007
            Multicast : current number=0 , max number=1024
            NDP : current number=2 , max number=15360
        Multipath table entry : current number=0 , max number=512
        MAC-Address table entry : current number=1014 , max number=81920
        VXLAN Layer2 Nexthop entry : current number=0 , max number=0
        System Layer2 Table Mode : mode=0
        Flow detection mode : layer3-mirror-5
          Used resources for filter inbound(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/1024    2/1024
          Used resources for QoS(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/ 512       n/a
          Used resources for UPC(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/ 512       n/a
          Used resources for Mirror inbound(Used/Max)
                    MAC      IPv4      IPv6
                 2/ 512    3/ 512    0/ 512
          Used resources for TCP/UDP port detection pattern
            Resources(Used/Max):  1/32
              Destination Port   Used 
                100-200        :       -/  -/mirror
        Flow detection out mode : layer3-2-out
          Used resources for filter outbound(Used/Max)
                    MAC      IPv4      IPv6
                 0/ 256    0/ 256    0/ 256
        Flow action change
            cos                : enable
            arp discard class  : enable
            arp reply cos      : enable
>

You can check the status of the fan and power supply unit, the temperature, and the total operating hours using the show environment operation command. The operation mode of the fan can be set using the system fan mode configuration command. An example is shown below:

Figure 14-3: Checking the device's environmental status
> show environment
Date 20XX/12/10 10:00:00 UTC
Power slot 1 : PS-M(AC)
Power slot 2 : PS-M(AC)
Fan slot     : FAN-M
 
Fan environment
    Power slot 1 : Fan1(1) = active
                   Speed = --------
    Power slot 2 : Fan2(1) = active
                   Speed = --------
    Fan slot     : Fan3(1) = active
                   Fan3(2) = active
                   Fan3(3) = active
                   Fan3(4) = active
                   Speed = normal
    Fan mode     : 1 (silent)
 
Power environment
    Power slot 1 : active
    Power slot 2 : active
 
Temperature environment
    Main  :  30 degrees C
    Warning level : normal
 
Accumulated running time
    Main         :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Power slot 1 :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Power slot 2 :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Fan slot     :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
>

The temperature-logging parameter of the show environment command allows you to check the temperature log. An example is shown below:

Figure 14-4: Checking temperature history information
> show environment temperature-logging
Date 20XX/12/10 20:00:00 UTC
Date         0:00  6:00 12:00 18:00
20XX/12/10      -     -  26.0  24.0
20XX/12/09   22.2  24.9  26.0  24.0
20XX/12/08   24.0  23.5  26.0  24.0
20XX/12/07   21.0     -  26.0  24.0
20XX/12/06   25.6     -  26.0  24.0
20XX/12/05   21.8  25.1  26.0  24.0
20XX/12/04   24.3  24.2  26.0
>