Message and Log Reference


2.9 POE

This section describes the operation messages for the event location POE.

Table 2-16: Operation messages for event location POE

Message

ID

Event

Level

Message text

Content and response

39000001

E3

Initialization PoE configuration.

Configure PoE settings.

[Action]

None.

39000003

E3

<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the overload detection.

Power supply was stopped because an overload was detected.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Check the devices receiving the power.

If devices to which PoE power can be supplied are connected, use the power inline configuration command to disable PoE on the target port.

39000004

E3

<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the thermal shutdown.

Power was stopped because a thermal error was detected in PoE controllers.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Review the installation environment of the equipment and reconnect.

39000005

E3

<switch no.>/<nif no.>/<port no.> Supplying power was stopped by the PD disorder.(xxxx)

Power supply was stopped because a failure of the power receiving device was detected.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

(xxxx) Power supply stop factor

[Action]

Execute activate power inline commandPlease do. If it does not recover, check the power receiving device or cable, and connect again.

39000006

E3

<switch no.>/<nif no.>/<port no.> Unable to supply power by the power shortage.

Power cannot be supplied due to a power shortage of the entire equipment.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

If you want to power this port, use show power inline commandto check Threshold and Allocate, and reduce the number of connected powered devices so that Allocate is below Threshold.

Alternatively, use the configuration command power inline to change the priorities.

Review the settings, and then execute activate power inline commandPlease.

39000009

E8

Init controller failed.

Failed to set PoE configuration.

[Action]

None. The appliance automatically restarts.

3900000a

E8

PoE controller access failed.(xxxx)

Accessing PoE controllerfailed.

(xxxx) Cause code (manufacturer analysis information)

[Action]

None. The appliance automatically restarts.