運用コマンドレファレンス Vol.1
運用状態を表示します。
[入力形式]
show system
[入力モード]
一般ユーザモードおよび装置管理者モード
[パラメータ]
なし
[実行例1]
通常運用時の表示例を次に示します。
図10-10 通常運用時の表示例【AX6700S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6708S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5101 Device redundancy cpu status : duplex Power control : normal Power redundancy-mode : check is executed PS1 = active PS2 = active PS3 = active PS4 = active PS5 = notconnect PS6 = notconnect PS7 = notconnect PS8 = notconnect Fan: active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5), FAN2(6), FAN3(7), FAN3(8), FAN3(9), FAN4(10), FAN4(11), FAN4(12) Speed = normal BCU1 : active CPU: AX-F6700-2S1[BCU-S1 , 80200020] Boot : 20XX/04/10 18:35:42 , power on , 0 times restart Lamp : STATUS LED=green , ACTIVE LED=green SYSTEM1 LED=green , SYSTEM2 LED=light off System operation panel : No error Board : CPU=PowerPC 833MHz , Memory=2,097,152kB(2048MB) Management port: active up 10BASE-T half(auto) , 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 63,470kB 91kB 6,326kB 69,887kB free 29,872kB 19,318kB 14,734kB 63,924kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total BCU2 : standby CPU: AX-F6700-2S1[BCU-S1 , 80200020] Boot : 20XX/04/10 18:36:25 , power on , 0 times restart Lamp : STATUS LED=green , ACTIVE LED=light off SYSTEM1 LED=green , SYSTEM2 LED=light off System operation panel : No error Board : CPU=PowerPC 833MHz , Memory=2,097,152kB(2048MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 62,699kB 91kB 4,800kB 67,590kB free 30,643kB 19,318kB 16,260kB 66,221kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 22,863kB used 100,096kB free 122,959kB total Redundancy bsu-load-balancing : port Redundancy bsu-mode : fail-safe BSU1 : active AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =green , ACTIVE LED=green, 0 times restart BSU2 : fault AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =red , ACTIVE LED=light off, 0 times restart BSU3 : active AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =green , ACTIVE LED=green, 0 times restart Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 32768 >図10-11 通常運用時の表示例【AX6600S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6608S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5102 Device redundancy cpu status : duplex Power control : normal Power redundancy-mode : check is executed PS1 = active PS2 = active PS3 = notconnect PS4 = notconnect PS5 = notconnect PS6 = notconnect Fan:active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5),FAN2(6), FAN3(7), FAN3(8),FAN3(9) Speed = normal CSU1 : active CPU:AX-F6600-41A [CSU-1A , AE0CSU1A0000045318AE071] Boot : 20XX/04/10 13:55:35 , power on , 0 times restart PSP : active Lamp : STATUS LED=green , ACTIVE LED=green SYSTEM1 LED=green , SYSTEM2 LED=light off System operation panel : No error Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: active up 10BASE-T half(auto) , 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 35,645kB 111kB 0kB 35,756kB free 247,119kB 282,775kB 163,660kB 693,554kB total 282,764kB 282,886kB 163,660kB 729,310kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total CSU2 : standby CPU:AX-F6600-41A [CSU-1A , AE0CSU1A0000045318AH071] Boot : 20XX/04/10 13:56:10 , power on , 0 times restart PSP : active Lamp : STATUS LED=green , ACTIVE LED=light off SYSTEM1 LED=green , SYSTEM2 LED=light off System operation panel : No error Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 35,631kB 111kB 0kB 35,742kB free 247,133kB 282,775kB 163,660kB 693,568kB total 282,764kB 282,886kB 163,660kB 729,310kB MC : enabled Manufacture ID : 00000003 22,863kB used 100,096kB free 122,959kB total Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 32768 >図10-12 通常運用時の表示例【AX6300S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6308S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5100 Device redundancy cpu status : duplex Power control : normal Power redundancy-mode : check is executed PS1 = active PS2 = active PS3 = notconnect PS4 = notconnect PS5 = notconnect PS6 = notconnect Fan:active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5),FAN2(6), FAN3(7), FAN3(8),FAN3(9) Speed = normal MSU1 : active CPU:AX-F6300-51A [MSU-1A , 80200020] Boot : 20XX/06/24 18:35:42 , power on , 0 times restart PSP : active Lamp : STATUS LED=green , ACTIVE LED=green , SYSTEM1 LED=green System operation panel : No error Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: active up 10BASE-T half(auto) , 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 63,470kB 91kB 6,326kB 69,887kB free 29,872kB 19,318kB 14,734kB 63,924kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total MSU2 : standby CPU:AX-F6300-51A [MSU-1A , 80200020] Boot : 20XX/06/24 18:36:25 , power on , 0 times restart PSP : standby Lamp : STATUS LED=green , ACTIVE LED=light off , SYSTEM1 LED=green System operation panel : No error Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 62,699kB 91kB 4,800kB 67,590kB free 30,643kB 19,318kB 16,260kB 66,221kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 22,863kB used 100,096kB free 122,959kB total Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 24576 >
[実行例2]
待機系システム異常時の表示例を次に示します。
図10-13 待機系システム異常時の表示例【AX6700S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6708S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5101 Device redundancy cpu status : simplex Power control : normal(changing suspended) Power redundancy-mode : check is not executed PS1 = active PS2 = active PS3 = active PS4 = active PS5 = notconnect PS6 = notconnect PS7 = notconnect PS8 = notconnect Fan: active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5), FAN2(6), FAN3(7), FAN3(8), FAN3(9), FAN4(10), FAN4(11), FAN4(12) Speed = normal BCU1 : active CPU: AX-F6700-2S1[BCU-S1 , 80200020] Boot : 20XX/04/10 18:35:42 , operation reboot , 0 times restart Lamp : STATUS LED=green , ACTIVE LED=green SYSTEM1 LED=orange , SYSTEM2 LED=light off System operation panel : Event level : E7 Location of event occurrence : SOFTWARE Message identifier : 01600001 Event occurrence interface identifier : none Board : CPU=PowerPC 833MHz , Memory=2,097,152kB(2048MB) Management port: active up 10BASE-T half(auto) 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 62,699kB 91kB 4,800kB 67,590kB free 30,643kB 19,318kB 16,260kB 66,221kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : notconnect BCU2 : fault CPU: AX-F6700-2S1[BCU-S1 , 80200020] Boot : 20XX/04/10 18:36:25, fatal , 1 times restart Lamp : STATUS LED=red , ACTIVE LED=light off SYSTEM1 LED=red , SYSTEM2 LED=light off System operation panel : Event level : E8 Location of event occurrence : BCU Message identifier : 800000000 Event occurrence interface identifier : none Board : CPU=PowerPC 833MHz , Memory=2,097,152kB(2048MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 63,470kB 91kB 6,326kB 69,887kB free 29,872kB 19,318kB 14,734kB 63,924kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total Redundancy bsu-load-balancing : port Redundancy bsu-mode : fail-safe BSU1 : active AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =green , ACTIVE LED=green, 0 times restart BSU2 : fault AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =red , ACTIVE LED=light off, 0 times restart BSU3 : active AX-F6700-3LA [BSU-LA] Lamp : STATUS LED =green , ACTIVE LED=green, 0 times restart Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 32768 >図10-14 待機系システム異常時の表示例【AX6600S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6608S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5102 Device redundancy cpu status : simplex Power control : normal(changing suspended) Power redundancy-mode : check is not executed PS1 = active PS2 = active PS3 = notconnect PS4 = notconnect PS5 = notconnect PS6 = notconnect Fan:active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5),FAN2(6), FAN3(7), FAN3(8),FAN3(9) Speed = normal CSU1 : active CPU : AX-F6600-41A [CSU-1A , AE0CSU1A0000045318AE071] Boot : 20XX/04/10 15:40:31 , operation reboot , 1 times restart PSP : active Lamp : STATUS LED=green , ACTIVE LED=green SYSTEM1 LED=orange , SYSTEM2 LED=light off System operation panel : Event level : E7 Location of event occurrence : SOFTWARE Message identifier : 01600001 Event occurrence interface identifier : none Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: active up 10BASE-T half(auto) 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 35,645kB 111kB 0kB 35,756kB free 247,119kB 282,775kB 163,660kB 693,554kB total 282,764kB 282,886kB 163,660kB 729,310kB MC : notconnect CSU2 : fault CPU : AX-F6600-41A [CSU-1A , AE0CSU1A0000045318AH071] Boot : 20XX/04/10 15:41:43, fatal , 1 times restart PSP : fault Lamp : STATUS LED=red , ACTIVE LED=light off SYSTEM1 LED=orange , SYSTEM2 LED=light off System operation panel : Event level : E8 Location of event occurrence : CSU Message identifier : 800000000 Event occurrence interface identifier : none Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 35,631kB 111kB 0kB 35,742kB free 247,133kB 282,775kB 163,660kB 693,568kB total 282,764kB 282,886kB 163,660kB 729,310kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 32768 >図10-15 待機系システム異常時の表示例【AX6300S】
> show system Date 20XX/07/15 12:00:00 UTC System: AX6308S, OS-SE Ver. 11.2 Node : Name=System Name Contact=Contact Address Locate=Location Elapsed time : 2days 03:25:01 Machine ID : 0012.e220.5100 Device redundancy cpu status : simplex Power control : normal Power redundancy-mode : check is not executed PS1 = active PS2 = active PS3 = notconnect PS4 = notconnect PS5 = notconnect PS6 = notconnect Fan:active No = FAN1(1), FAN1(2), FAN1(3), FAN2(4), FAN2(5),FAN2(6), FAN3(7), FAN3(8),FAN3(9) Speed = normal MSU1 : active CPU : AX-F6300-51A [MSU-1A , 80200020] Boot : 20XX/06/24 18:35:42 , operation reboot , 1 times restart PSP : active Lamp : STATUS LED=green , ACTIVE LED=green , SYSTEM1 LED=orange System operation panel : Event level : E7 Location of event occurrence : SOFTWARE Message identifier : 01600001 Event occurrence interface identifier : none Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: active up 10BASE-T half(auto) 0012.e220.3401 Temperature : normal(27degree) Flash : user area config area dump area area total used 62,699kB 91kB 4,800kB 67,590kB free 30,643kB 19,318kB 16,260kB 66,221kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : notconnect MSU2 : fault CPU : AX-F6300-51A [MSU-1A , 80200020] Boot : 20XX/06/24 18:36:25, fatal , 1 times restart PSP : fault Lamp : STATUS LED=red , ACTIVE LED=light off , SYSTEM1 LED=red System operation panel : Event level : E8 Location of event occurrence : MSU Message identifier : 800000000 Event occurrence interface identifier : none Board : CPU=PowerPC 667MHz , Memory=1,048,576kB(1024MB) Management port: unused Temperature : normal(25degree) Flash : user area config area dump area area total used 63,470kB 91kB 6,326kB 69,887kB free 29,872kB 19,318kB 14,734kB 63,924kB total 93,342kB 19,409kB 21,060kB 133,811kB MC : enabled Manufacture ID : 00000003 19,343kB used 103,616kB free 122,959kB total Forwarding Database Management fwdm : ipv4-uni standard IPv4 Unicast resources Used/Max: 0 / 65536 IPv4 Multicast resources Used/Max: 0 / 0 IPv6 Unicast resources Used/Max: 0 / 0 IPv6 Multicast resources Used/Max: 0 / 0 MAC Address resources Used/Max: 0 / 24576 MAC Address (Learned) used : 0 MAC Address (Static) used : 0 MAC Address (IEEE802.1X/Web/MAC) used : 0 MAC Address (not Learned/ARP,NDP resolved) used : 0 VLAN config used : 0 MAC Address (IGMP/MLD Snooping) used : 0 Shared resources Used/Max: 0B/1638400B IPv4 Unicast Single-path used : 0B IPv4 Unicast Multi-path used : 0B IPv6 Unicast Single-path used : 0B IPv6 Unicast Multi-path used : 0B IPv4 Multicast used : 0B IPv6 Multicast used : 0B IPv4 Policy Based Routing used: 0B IPv6 Policy Based Routing used: 0B Policy Based Switching used : 0B VLAN config used : 0B IGMP/MLD Snooping used : 0B Flow Database Management fldm : default standard-advance Filter resources Used/Max: 1856/ 4000 MAC : 239 IPv4 : 1046 IPv6 : 571 Advance : 0 QoS resources Used/Max: 1206/ 4000 MAC : 18 IPv4 : 814 IPv6 : 374 Advance : 0 upc-storm-control mode : upc-in-and-storm-control UPC resources Used/Max: 145/ 744 MAC : 100 IPv4 : 30 IPv6 : 15 Advance : 0 Hierarchical shaper Database Management User: 1024/ 24576 >
[実行例1,2の表示説明]
表10-4 show systemコマンド表示内容(1/8)
表示項目 表示内容 表示詳細情報 System 装置モデル 装置モデル ソフトウェア情報 ソフトウェア種別,バージョン Node ノード情報 − Name システム名称 ユーザが設定する識別名称 Contact 連絡先 ユーザが設定する連絡先 Locate 設置場所 ユーザが設定する設置場所 Elapsed time 経過時間 装置起動後からの経過時間 Machine ID 筐体MACアドレス 筐体MACアドレス Device redundancy cpu status CPU冗長ステータス duplex:二重化正常運用中
simplex:一重化正常運用中Power control 電力制御モード【AX6700S】【AX6600S】 normal:通常電力で運用します。
saving mode1:省電力モード1で運用します。
saving mode2:省電力モード2で運用します。
changing:電力制御モード変更中。
スケジューリングまたはトラフィック量による電力制御モード変更が実行できなかった場合,(changing suspended)を付けて表示します。電力制御モード【AX6300S】 normal:通常電力で運用します。
saving:省電力で運用します。Power redundancy-mode 電源運用モード check is executed:電源が冗長構成かのチェックを行います。
check is not executed:電源が冗長構成かのチェックを行いません。PS 入力電源の実装状態 active:正常供給
fault:供給なし/電圧異常
notconnect:未実装Fan※ ファン動作状態 稼働状態となっているファン番号 ファン回転スピード normal:通常回転
high:高速回転
stop:停止状態注※ FANx(y)のフォーマットでファンの位置情報を記載していますが,xの値はファンユニット番号を,yの値はファン番号を示します。このとき,運用ログや筐体に明記されている名称との対応は次の表のようになります。また,筐体位置で示される前面,中面,後面は装置背面から見た場合の位置関係を表します。
表10-5 ファン番号と運用ログおよび筐体との対応
装置モデル ファンユニット対応 筐体 ユニット コマンドおよび運用ログ表示 筐体位置 AX6708S FAN1 FAN1(1) 上段ファンユニット前面 FAN1(2) 上段ファンユニット中面 FAN1(3) 上段ファンユニット後面 FAN2 FAN2(4) 中段上ファンユニット前面 FAN2(5) 中段上ファンユニット中面 FAN2(6) 中段上ファンユニット後面 FAN3 FAN3(7) 中段下ファンユニット前面 FAN3(8) 中段下ファンユニット中面 FAN3(9) 中段下ファンユニット後面 FAN4 FAN4(10) 下段ファンユニット前面 FAN4(11) 下段ファンユニット中面 FAN4(12) 下段ファンユニット後面 AX6604S FAN1 FAN1(1) 上段ファンユニット前面 FAN1(2) 上段ファンユニット中面 FAN1(3) 上段ファンユニット後面 FAN2 FAN2(4) 下段ファンユニット前面 FAN2(5) 下段ファンユニット中面 FAN2(6) 下段ファンユニット後面 AX6608S FAN1 FAN1(1) 上段ファンユニット前面 FAN1(2) 上段ファンユニット中面 FAN1(3) 上段ファンユニット後面 FAN2 FAN2(4) 中段ファンユニット前面 FAN2(5) 中段ファンユニット中面 FAN2(6) 中段ファンユニット後面 FAN3 FAN3(7) 下段ファンユニット前面 FAN3(8) 下段ファンユニット中面 FAN3(9) 下段ファンユニット後面 AX6304S FAN1 FAN1(1) 上段ファンユニット前面 FAN1(2) 上段ファンユニット中面 FAN1(3) 上段ファンユニット後面 FAN2 FAN2(4) 下段ファンユニット前面 FAN2(5) 下段ファンユニット中面 FAN2(6) 下段ファンユニット後面 AX6308S FAN1 FAN1(1) 上段ファンユニット前面 FAN1(2) 上段ファンユニット中面 FAN1(3) 上段ファンユニット後面 FAN2 FAN2(4) 中段ファンユニット前面 FAN2(5) 中段ファンユニット中面 FAN2(6) 中段ファンユニット後面 FAN3 FAN3(7) 下段ファンユニット前面 FAN3(8) 下段ファンユニット中面 FAN3(9) 下段ファンユニット後面 表10-6 show systemコマンド表示内容(2/8)【AX6700S】
表示項目 表示内容 表示詳細情報 BCU BCUの動作状態 active:運用系として稼働中
standby:待機系として稼働中
fault:障害中※1
initialize:初期化中
inactive:inactive状態
notconnect:未実装
configuration discord:コンフィグレーションの不一致により運用系と非同期中※2
software version discord:ソフトウェアバージョンの不一致により運用系と非同期中※2
license key discord:ライセンスキーの不一致により運用系と非同期中※2CPU BCU情報 BCUの型名,略称,CPUバージョン情報 Boot CPUの起動時刻 CPUの起動時刻 CPUの起動要因 power on:電源スイッチONによる起動
operation reboot:再起動コマンド,または系切替スイッチ押下による再起動
fatal:再起動(障害発生)
hardware reset:リセットスイッチによる再起動
default restart:デフォルトリスタートによる再起動
auto restart:ソフトウェアによる自動再起動障害によるCPUの再起動回数 装置障害によるCPUの再起動回数※3 Lamp LED表示 − STATUS LED 装置状態の表示LED light off:消灯
green:緑点灯
orange:橙点灯
red:赤点灯ACTIVE LED BCU冗長運用状態の表示LED light off:消灯
green:緑点灯SYSTEM1 LED BCU動作状態の表示LED light off:消灯
orange:橙点灯
green blink:緑点滅
green:緑点灯
red:赤点灯SYSTEM2 LED 電力制御モードの表示LED light off:消灯
green blink:緑点滅
green:緑点灯System operation panel システム操作パネルの情報表示※4 − Event level イベントレベル※5 イベントレベルの表示
注 複数の障害が発生中の場合は,最もイベントレベルの高い障害情報を表示します。Location of event occurrence イベント発生部位※5 イベント発生部位の表示 Message identifier メッセージ識別子※5 メッセージ識別子の表示 Event occurrence interface identifier イベント発生インタフェース識別子※5 イベント発生インタフェース識別子の表示 Board BCUの情報 BCUの種別,クロック,CPUバージョン情報 BCUの実装メモリサイズ BCUの実装メモリサイズ Management port マネージメントポートステータス※6 active up:運用中(正常動作中)
active down:運用中(回線障害発生中)
unused:未使用
inactive:inactive状態
test:回線テスト中
disable:コンフィグレーションで運用停止中回線速度 10BASE-T half:10BaseT 半二重
10BASE-T half(auto):10BaseT 半二重
10BASE-T full:10BaseT 全二重
10BASE-T full(auto):10BaseT 全二重
100BASE-TX half:100BaseTx 半二重
100BASE-TX half(auto):100BaseTx 半二重
100BASE-TX full:100BaseTx 全二重
100BASE-TX full(auto):100BaseTx 全二重MACアドレス マネージメントポートのMACアドレス Description 該当マネージメントポートに設定したDescriptionコンフィグレーションの内容
注 Descriptionコンフィグレーションを設定していない場合は表示しません。Temperature 入気温度情報 normal:正常
caution:注意(高温または低温)
critical:警告
fault:異常
注 温度センサーが65℃以上になると,ソフトウェアが停止します。
- 注※1 以下の状態の場合に本ステータスを表示します。
- H/W障害が発生した場合
- 運用系と待機系のBCUボード種別が不一致のため運用停止状態の場合
- サポート対象外のBCUボードを実装しているため運用停止状態の場合
- 実装しているBCUボードで使用できないコンフィグレーションが設定されているため運用停止状態の場合
- BCUの復旧が抑止されている場合
- また,待機系BCUの起動直後に本コマンドを実行した場合にも,一時的に本ステータスを表示します。待機系BCUが本ステータスのまま移行しないときは,ハードウェア診断によって異常を検知したことを示します。
- 注※2 BCUの動作状態を表示する際,"configuration discord","software version discord","license key discord"は,同時に発生する場合があるため,複数行にわたり表示することがあります。
- <表示例>
- BCU1 : configuration discord
- software version discord
- license key discord
- 注※3 装置の再起動から1時間以上経過すると初期化されます。
- 注※4 障害が発生していない場合は,"'No error"を表示します。
- 注※5 システム操作パネルで"No error"を表示している場合は,本項目を表示しません。
- 注※6 コンフィグレーションコマンドsaveによるコンフィグレーションの保存中,またはcopyコマンドによるコンフィグレーションのコピー中は,"--------"を表示し,回線速度とMACアドレスは表示しません。
表10-7 show systemコマンド表示内容(3/8)【AX6600S】
表示項目 表示内容 表示詳細情報 CSU CSUの動作状態 active:運用系として稼働中
standby:待機系として稼働中
fault:障害中※1
initialize:初期化中
inactive:inactive状態
notconnect:未実装
configuration discord:コンフィグレーション不一致により運用系と非同期中※2
software version discord:S/Wバージョン不一致により運用系と非同期中※2
license key discord:ライセンスキー不一致により運用系と非同期中※2CPU CSU情報 CSUの型名,略称,CPUバージョン情報 Boot CPUの起動時刻 CPUの起動時刻 CPUの起動要因 power on:電源スイッチONによる起動
operation reboot:再起動コマンド,またはACHスイッチ押下による再起動
fatal:再起動(障害発生)
hardware reset:リセットスイッチによる再起動
default restart:デフォルトリスタートによる再起動
auto restart:ソフトウェアによる自動再起動障害によるCPUの再起動回数 装置障害によるCPUの再起動回数※3 PSP PSPの動作状態 active:運用系として稼働中
standby hot:待機系(ホットスタンバイ)として稼働中
standby cold2:待機系(コールドスタンバイ2)として稼働中
fault:障害中※1
initialize:初期化中Lamp LED表示 − STATUS LED 装置状態表示LED light off:消灯
green:緑点灯
orange:橙点灯
red:赤点灯ACTIVE LED CSU冗長運用状態表示LED light off:消灯
green:緑点灯SYSTEM1 LED CSU動作状態表示LED light off:消灯
orange:橙点灯
green blink:緑点滅
green:緑点灯
red:赤点灯SYSTEM2 LED 電力制御モードの表示LED light off:消灯
green blink:緑点滅
green:緑点灯System operation panel システム操作パネルの情報表示※4 − Event level イベントレベル※5 イベントレベルの表示
注 複数の障害が発生中の場合は,最もイベントレベルの高い障害情報を表示します。Location of event occurrence イベント発生部位※5 イベント発生部位の表示 Message identifier メッセージ識別子※5 メッセージ識別子の表示 Event occurrence interface identifier イベント発生インタフェース識別子※5 イベント発生インタフェース識別子の表示 Board CPUの情報 CPUの種別,クロック CSUの実装メモリサイズ CSUの実装メモリサイズ Management port マネージメントポートステータス※6 active up:運用中(正常動作中)
active down:運用中(回線障害発生中)
unused:未使用
inactive:inactive状態
test:回線テスト中
disable:コンフィグレーションで運用停止中回線速度 10BASE-T half:10BaseT 半二重
10BASE-T half(auto):10BaseT 半二重
10BASE-T full:10BaseT 全二重
10BASE-T full(auto):10BaseT 全二重
100BASE-TX half:100BaseTx 半二重
100BASE-TX half(auto):100BaseTx 半二重
100BASE-TX full:100BaseTx 全二重
100BASE-TX full(auto):100BaseTx 全二重MACアドレス マネージメントポートのMACアドレス Description 該当マネージメントポートに設定したDescriptionコンフィグレーションの内容
注 Descriptionコンフィグレーションを設定していない場合は表示しません。Temperature 入気温度情報 normal:正常
caution:注意(高温または低温)
critical:警告
fault:異常
注 温度センサーが65℃以上になると,ソフトウェアが停止します。
- 注※1 以下の状態の場合に本ステータスを表示します。
- H/W障害が発生した場合
- 運用系と待機系のCSUボード種別が不一致のため運用停止状態の場合
- サポート対象外CSUボードを実装しているため運用停止状態の場合
- 実装しているCSUボードで使用できないコンフィグレーションが設定されているため運用停止状態の場合
- CSUの復旧が抑止されている場合
- また,待機系CSUの起動直後に本コマンドを実行した場合にも,一時的に本ステータスを表示します。待機系CSUが本ステータスのまま移行しないときは,ハードウェア診断によって異常を検知したことを示します。
- 注※2 CSUの動作状態を表示する際,"configuration discord","software version discord","license key discord"は,同時に発生する場合があるため,複数行にわたり表示することがあります。
- <表示例>
- CSU1 : configuration discord
- software version discord
- license key discord
- 注※3 装置の再起動から1時間以上経過すると初期化されます。
- 注※4 障害が発生していない場合は,"No error"を表示します。
- 注※5 システム操作パネルで"No error"を表示している場合は,本項目を表示しません。
- 注※6 コンフィグレーションコマンドsaveでコンフィグレーションを保存中またはcopyコマンドでコンフィグレーションをコピー中は"--------"を表示し,回線速度およびMACアドレスは表示しません。
表10-8 show systemコマンド表示内容(4/8)【AX6300S】
表示項目 表示内容 表示詳細情報 MSU MSUの動作状態 active:運用系として稼働中
standby:待機系として稼働中
fault:障害中※1
initialize:初期化中
inactive:inactive状態
notconnect:未実装
configuration discord:コンフィグレーション不一致により運用系と非同期中※2
software version discord:S/Wバージョン不一致により運用系と非同期中※2
license key discord:ライセンスキー不一致により運用系と非同期中※2CPU MSU情報 MSUの型名,略称,CPUバージョン情報 Boot CPUの起動時刻 CPUの起動時刻 CPUの起動要因 power on:電源スイッチONによる起動
operation reboot:再起動コマンド,またはACHスイッチ押下による再起動
fatal:再起動(障害発生)
hardware reset:リセットスイッチによる再起動
default restart:デフォルトリスタートによる再起動
auto restart:ソフトウェアによる自動再起動障害によるCPUの再起動回数 装置障害によるCPUの再起動回数※3 PSP PSPの動作状態 active:運用系として稼働中
standby:待機系として稼働中
fault:障害中※1
initialize:初期化中Lamp LED表示 − STATUS LED 装置状態表示LED light off:消灯
green:緑点灯
orange:橙点灯
red:赤点灯ACTIVE LED MSU冗長運用状態表示LED light off:消灯
green:緑点灯SYSTEM1 LED MSU動作状態表示LED light off:消灯
orange:橙点灯
green blink:緑点滅
green:緑点灯
red:赤点灯System operation panel システム操作パネルの情報表示※4 − Event level イベントレベル※5 イベントレベルの表示
注 複数の障害が発生中の場合は,最もイベントレベルの高い障害情報を表示します。Location of event occurrence イベント発生部位※5 イベント発生部位の表示 Message identifier メッセージ識別子※5 メッセージ識別子の表示 Event occurrence interface identifier イベント発生インタフェース識別子※5 イベント発生インタフェース識別子の表示 Board CPUの情報 CPUの種別,クロック MSUの実装メモリサイズ MSUの実装メモリサイズ Management port マネージメントポートステータス※6 active up:運用中(正常動作中)
active down:運用中(回線障害発生中)
unused:未使用
inactive:inactive状態
test:回線テスト中
disable:コンフィグレーションで運用停止中回線速度 10BASE-T half:10BaseT 半二重
10BASE-T half(auto):10BaseT 半二重
10BASE-T full:10BaseT 全二重
10BASE-T full(auto):10BaseT 全二重
100BASE-TX half:100BaseTx 半二重
100BASE-TX half(auto):100BaseTx 半二重
100BASE-TX full:100BaseTx 全二重
100BASE-TX full(auto):100BaseTx 全二重MACアドレス マネージメントポートのMACアドレス Description 該当マネージメントポートに設定したDescriptionコンフィグレーションの内容
注 Descriptionコンフィグレーションを設定していない場合は表示しません。Temperature 入気温度情報 normal:正常
caution:注意(高温または低温)
critical:警告
fault:異常
注 温度センサーが65℃以上になると,ソフトウェアが停止します。
- 注※1 以下の状態の場合に本ステータスを表示します。
- H/W障害が発生した場合
- 運用系と待機系のMSUボード種別が不一致のため運用停止状態の場合
- サポート対象外MSUボードを実装しているため運用停止状態の場合
- 実装しているMSUボードで使用できないコンフィグレーションが設定されているため運用停止状態の場合
- MSUの復旧が抑止されている場合
- また,待機系MSUの起動直後に本コマンドを実行した場合にも,一時的に本ステータスを表示します。待機系MSUが本ステータスのまま移行しないときは,ハードウェア診断によって異常を検知したことを示します。
- 注※2 MSUの動作状態を表示する際,"configuration discord","software version discord","license key discord"は,同時に発生する場合があるため,複数行にわたり表示することがあります。
- <表示例>
- MSU1 : configuration discord
- software version discord
- license key discord
- 注※3 装置の再起動から1時間以上経過すると初期化されます。
- 注※4 障害が発生していない場合は,"No error"を表示します。
- 注※5 システム操作パネルで"No error"を表示している場合は,本項目を表示しません。
- 注※6 コンフィグレーションコマンドsaveでコンフィグレーションを保存中またはcopyコマンドでコンフィグレーションをコピー中は"--------"を表示し,回線速度およびMACアドレスは表示しません。
表10-9 show systemコマンド表示内容(5/8)
表示項目 表示内容 表示詳細情報 Flash − Flash情報 Flash情報 used 使用容量 内蔵フラッシュメモリ上のファイルシステム使用容量※1
user area:ユーザ領域の使用容量
config area:コンフィグレーション領域の使用容量
dump area:ダンプ領域の使用容量
area total:ユーザ領域,コンフィグレーション領域,ダンプ領域の各使用容量の合計値free 未使用容量 内蔵フラッシュメモリ上のファイルシステム未使用容量※1
user area:ユーザ領域の未使用容量
config area:コンフィグレーション領域の未使用容量
dump area:ダンプ領域の未使用容量
area total:ユーザ領域,コンフィグレーション領域,ダンプ領域の各未使用容量の合計値total※2 合計容量 内蔵フラッシュメモリのファイルシステム使用容量と未使用容量の合計容量※1
user area:ユーザ領域の使用容量と未使用容量の合計容量
config area:コンフィグレーション領域の使用容量と未使用容量の合計容量
dump area:ダンプ領域の使用容量と未使用容量の合計容量
area total:内蔵フラッシュメモリのファイルシステム使用容量と未使用容量の合計容量MC − MCの状態 enabled:MCのアクセス可能
notconnect:MC未実装
write protect:MC書き込み禁止状態
--------:ほかのプロセスがMCにアクセスしている状態※3Manufacture ID 製造ID番号※4 MCの製造ID番号 used 使用容量※4 MC上のファイルシステム使用容量 free 未使用容量※4 MC上のファイルシステム未使用容量 total 合計容量※4 MC上のファイルシステム使用容量と未使用容量の合計容量 注※1 使用容量が全容量の95%を超過した場合に,未使用容量がマイナス表示となることがあります。未使用容量がマイナス表示となる場合,ユーザファイルを削除して,未使用容量を確保してください。
注※2 同一型名のBCU/CSU/MSUでも,内蔵フラッシュメモリの使用容量が異なる場合があります。
注※3 ほかのプロセスがMCにアクセスしています。時間をおいて,再実行してください。
注※4 MCの状態がenabled,write protectのときに表示します。
表10-10 show systemコマンド表示内容(6/8)【AX6700S】
表示項目 表示内容 表示詳細情報 Redundancy bsu-load-balancing BSU負荷分散モード port:パケットを受信したポート番号に基づきBSUの負荷を分散します。
smac:パケットの送信元MACアドレスに基づきBSUの負荷を分散します。Redundancy bsu-mode BSU運転モード fail-safe:BSUの障害発生時,他の正常なBSUを使用して通信を継続します。
fixed:BSUの障害発生時,該当BSUの通信を回復しません。BSU BSUの動作状態 active:運用系として稼働中
standby hot:待機系(ホットスタンバイ)として稼働中
standby cold:待機系(コールドスタンバイ)として稼働中
standby cold2:待機系(コールドスタンバイ2)として稼働中
fault:障害中
inactive:次のどれかの状態
notconnect:未実装※1
- inactivateコマンドによる運用停止状態
- 未サポートボードが実装されている状態
- 異なる種類のボードが混在して実装されている状態
- コンフィグレーションコマンドredundancy bsu-modeで"fixed(固定モード)"が設定されており,かつ該当BSUの実装スロットの位置が"max-bsu"のコンフィグレーションと異なる状態
initialize:初期化中
disable:コンフィグレーションコマンドでno power enableが設定されていることによる運用停止状態BSU情報 BSUの型名,略称,BSUが障害によって再起動した回数※2 Lamp※3※4 LED表示 − STATUS LED BSU動作状態の表示LED light off:消灯
orange:橙点灯
green blink:緑点滅
green:緑点灯
red:赤点灯ACTIVE LED BSU冗長運用状態の表示LED light off:消灯
green:緑点灯注※1 BCUの復旧が抑止されている場合も本ステータスを表示します。
注※2 BSUが障害によって再起動した回数は,1時間ごとに初期化されます。
注※3 ハードウェアボードを未実装の場合,または未サポートのハードウェアボードを実装している場合,該当ハードウェアボードの表示項目「Lamp」は表示しません。
注※4 運用系のBSUで運用停止処理中の場合,STATUS LEDは消灯し,ACTIVE LEDが緑点灯します。
表10-11 show systemコマンド表示内容(7/8)
表示項目 表示内容 表示詳細情報 Forwarding Database Management − fwdm − コンフィグレーションで指定している経路系テーブルの最大テーブルエントリ数配分パターン default standard:全エントリ混在標準配分
ipv4-uni standard:IPv4ユニキャスト主体,マルチキャスト,IPv6なし標準配分
ipv4-ipv6-uni standard:IPv4ユニキャスト/IPv6ユニキャスト主体,マルチキャストなし標準配分
vlan standard:L2主体,マルチキャストなし標準配分
default extended:全エントリ混在拡張配分
ipv4-uni extended:IPv4ユニキャスト主体,マルチキャスト,IPv6なし拡張配分
ipv4-ipv6-uni extended:IPv4ユニキャスト/IPv6ユニキャスト主体,マルチキャストなし拡張配分
vlan extended:L2主体,マルチキャストなし拡張配分IPv4 Unicast resources Used/Max IPv4ユニキャスト経路テーブル使用量 装置全体のIPv4ユニキャスト経路テーブルの使用容量を表示します。
<Used>:使用エントリ数
<Max>:使用可能最大エントリ数IPv4 Multicast resources Used/Max IPv4マルチキャスト経路テーブル使用量 装置全体のIPv4マルチキャスト経路テーブルの使用容量を表示します。
<Used>:使用エントリ数
<Max>:使用可能最大エントリ数IPv6 Unicast resources Used/Max IPv6ユニキャスト経路テーブル使用量 装置全体のIPv6ユニキャスト経路テーブルの使用容量を表示します。
<Used>:使用エントリ数
<Max>:使用可能最大エントリ数IPv6 Multicast resources Used/Max IPv6マルチキャスト経路テーブル使用量 装置全体のIPv6マルチキャスト経路テーブルの使用容量を表示します。
<Used>:使用エントリ数
<Max>:使用可能最大エントリ数MAC Address resources Used/Max MACアドレスデータベース使用容量 装置全体のMACアドレスデータベースの使用容量を表示します。
<Used>:使用エントリ数
<Max>:使用可能最大エントリ数MAC Address (Learned) used MACアドレス学習によるMACアドレスデータベース使用容量を表示します。 MAC Address (Static) used Static MACアドレスまたはRing Protocol機能によるMACアドレスデータベース使用容量を表示します。 MAC Address (IEEE802.1X/Web/MAC) used IEEE802.1X,Web認証,MAC認証によるMACアドレスデータベース使用容量を表示します。 MAC Address (not Learned/ARP,NDP resolved) used 未学習MACアドレスのARP/NDPエントリによるMACアドレスデータベース使用容量を表示します。 VLAN config used MACアドレス学習停止設定によるMACアドレスデータベース使用容量を表示します。 MAC Address (IGMP/MLD Snooping) used IGMP/MLD SnoopingによるMACアドレスデータベース使用容量を表示します。 Shared resources Used/Max レイヤ2,レイヤ3の中継で使用する共有メモリの使用容量 装置全体の共有メモリの使用容量をバイト単位で表示します。
<Used>:使用容量(バイト)
<Max>:使用可能最大容量(バイト)IPv4 Unicast Single-path used IPv4ユニキャストシングルパス経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv4 Unicast Multi-path used IPv4ユニキャストマルチパス経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv6 Unicast Single-path used IPv6ユニキャストシングルパス経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv6 Unicast Multi-path used IPv6ユニキャストマルチパス経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv4 Multicast used IPv4マルチキャスト経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv6 Multicast used IPv6マルチキャスト経路によって消費する共有メモリの使用容量をバイト単位で表示します。 IPv4 Policy Based Routing used IPv4ポリシーベースルーティングによって消費する共有メモリの使用容量をバイト単位で表示します。 IPv6 Policy Based Routing used IPv6ポリシーベースルーティングによって消費する共有メモリの使用容量をバイト単位で表示します。 Policy Based Switching used ポリシーベーススイッチングによって消費する共有メモリの使用容量をバイト単位で表示します。 VLAN config used 0B固定 IGMP/MLD Snooping used IGMP/MLD Snoopingによって消費する共有メモリの使用容量をバイト単位で表示します。 表10-12 show systemコマンド表示内容(8/8)
表示項目 表示内容 表示詳細情報 Flow Database Management フローエントリ情報 fldm − コンフィグレーションコマンドで指定しているフィルタ・QoS機能のフロー配分パターンの内容 default standard:標準のフロー配分
default standard-advance:標準のフロー配分でフロー検出拡張モードを設定
default extended:フィルタとQoSを均等にした拡張フロー配分
default extended-advance:フィルタとQoSを均等にした拡張フロー配分でフロー検出拡張モードを設定
filter-only extended:フィルタだけの拡張フロー配分
filter-only extended-advance:フィルタだけの拡張フロー配分でフロー検出拡張モードを設定
qos-only extended:QoSだけの拡張フロー配分
qos-only extended-advance:QoSだけの拡張フロー配分でフロー検出拡張モードを設定
filter extended:フィルタ重視の拡張フロー配分
filter extended-advance:フィルタ重視の拡張フロー配分でフロー検出拡張モードを設定
qos extended:QoS重視の拡張フロー配分
qos extended-advance:QoS重視の拡張フロー配分でフロー検出拡張モードを設定Filter resources Used/Max: <Used>/<Max> インタフェースに適用し,フィルタ機能が有効となっているフィルタ条件のエントリ数と,適用可能な最大エントリ数 インタフェースに適用し,フィルタ機能が有効となっているフィルタ条件のエントリ数と,適用可能な最大エントリ数を表示します。適用エントリ数はコンフィグレーションで設定したフィルタ条件エントリと暗黙の廃棄エントリの装置全体での合計です。
<Used>:適用エントリ数
<Max>:適用可能最大エントリ数MAC : インタフェースに適用し,フィルタ機能が有効となっているMACアクセスリストのフィルタ条件のエントリ数を表示します。 IPv4 : インタフェースに適用し,フィルタ機能が有効となっているIPv4アクセスリストのフィルタ条件のエントリ数を表示します。 IPv6 : インタフェースに適用し,フィルタ機能が有効となっているIPv6アクセスリストのフィルタ条件のエントリ数を表示します。 Advance : fldmにフロー検出拡張モードを設定している場合にだけインタフェースに適用し,フィルタ機能が有効となっているAdvanceアクセスリストのフィルタ条件のエントリ数を表示します。 QoS resources Used/Max: <Used>/<Max> インタフェースに適用し,QoS機能が有効となっているフロー検出および動作指定のエントリ数と,適用可能な最大エントリ数 インタフェースに適用し,QoS機能が有効となっているフロー検出および動作指定のエントリ数と,適用可能な最大エントリ数を表示します。適用エントリ数はコンフィグレーションで設定したQoSのフロー検出および動作指定エントリの装置全体の合計です。
<Used>:適用エントリ数
<Max>:適用可能最大エントリ数MAC : インタフェースに適用し,QoS機能が有効となっているMAC Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 IPv4 : インタフェースに適用し,QoS機能が有効となっているIPv4 Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 IPv6 : インタフェースに適用し,QoS機能が有効となっているIPv6 Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 Advance : fldmにフロー検出拡張モードを設定している場合にだけインタフェースに適用し,QoS機能が有効となっているAdvance QoSフローリストのフロー検出および動作指定のエントリ数を表示します。 upc-storm-control mode − コンフィグレーションコマンドで指定しているQoS機能の帯域監視およびストームコントロールのモード upc-in-and-storm-control:受信側に最大帯域制御または最低帯域監視を設定可,ストームコントロール使用可
upc-in-in:受信側に最大帯域制御および最低帯域監視を設定可,ストームコントロール使用不可
upc-in-out:受信側および送信側に最大帯域制御または最低帯域監視を設定可,ストームコントロール使用不可UPC resources Used/Max: <Used>/<Max> インタフェースに適用し,QoS機能の帯域監視が有効となっているエントリ数と,適用可能な最大エントリ数 インタフェースに適用し,QoS機能の帯域監視が有効となっているエントリ数と,適用可能な最大エントリ数を表示します。適用エントリ数はコンフィグレーションでQoS機能の動作指定に帯域監視を指定したエントリの装置全体の合計です。
<Used>:適用エントリ数
<Max>:適用可能最大エントリ数MAC : インタフェースに適用し,QoS機能の帯域監視が有効となっているMAC Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 IPv4 : インタフェースに適用し,QoS機能の帯域監視が有効となっているIPv4 Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 IPv6 : インタフェースに適用し,QoS機能の帯域監視が有効となっているIPv6 Qosフローリストのフロー検出および動作指定のエントリ数を表示します。 Advance : fldmにフロー検出拡張モードを設定している場合にだけインタフェースに適用し,QoS機能の帯域監視が有効となっているAdvance QoSフローリストのフロー検出および動作指定のエントリ数を表示します。 Hierarchical shaper Database Management 階層化シェーパユーザエントリ情報 User <Used>/<Max> インタフェースに適用したユーザのエントリ数と,適用可能な最大エントリ数 インタフェースに適用したユーザのエントリ数と,適用可能な最大エントリ数を表示します。
<Used>:適用エントリ数
<Max>:適用可能最大エントリ数
なお,コンフィグレーションで階層化シェーパのシェーパ自動設定機能を設定したとき,適用エントリ数は次の式で算出します。
AX6700S/AX6600Sの場合:
指定ユーザ数×搭載可能NIF枚数×8ポート
AX6300Sの場合:
指定ユーザ数×搭載可能NIF枚数×6ポート
[通信への影響]
なし
[応答メッセージ]
表10-13 show systemコマンドの応答メッセージ一覧
メッセージ 内容 Can't execute this command in standby system. 本コマンドは待機系システムでは実行できません。 Can't execute. コマンドを実行できません。再実行してください。
[注意事項]
なし
All Rights Reserved, Copyright(C), 2006, 2018, ALAXALA Networks, Corp.