コンフィグレーションガイド Vol.1


14.1.3 装置の状態確認

運用コマンドshow systemで装置の動作状態や実装メモリ量などを確認できます。次の図に例を示します。

図14‒2 装置の状態確認
> show system
Date 20XX/01/16 17:53:12 UTC
System: AX3660S-48XT4QW, OS-L3M (SL-L3A-001) Ver. 12.1.D
Node : Name=
    Contact=
    Locate=
    Elapsed time : 00:45:03
    LED Brightness mode : normal
    Machine ID : 0012.e23e.b20f
    Power redundancy-mode : check is not executed
    Power slot 1 : active PS-M(AC)
        Fan  : active No = Fan1(1)  Speed = --------, Direction = F-to-R
        PS   : active
    Power slot 2 : notconnect
    Fan slot : active FAN-M
        Fan  : active No = Fan3(1) , Fan3(2) , Fan3(3) , Fan3(4)
               Speed = normal , Direction = F-to-R
        Lamp : ALM LED=light off
    Main board : active
        Boot : 20XX/01/16 17:08:19 , operation reboot
        Fatal restart : CPU 0 times ,  SW 0 times
        Lamp : Power LED=green , Status LED1=green
        Board : CPU=AMD GX-420 2000MHz , Memory=4,194,304KB(4096MB)
        Management port: active up
             100BASE-TX full(auto) 0012.e23e.b20f
        Temperature : normal(26degree)
        Flash :
                  user area   config area     dump area    area total
            used  238,599KB          99KB           0KB     238,698KB 
            free  229,857KB     116,963KB     131,008KB     477,828KB 
            total 468,456KB     117,062KB     131,008KB     716,526KB
        MC  : enabled
            Manufacture ID : 00000030
            24,077KB used
            971,008KB free
            995,085KB total
        System interface hundredgigabitethernet : 
            disable (10G)  : 0/21-22,37-44
            enable  (100G) : 0/49,51-52
    Device resources
        Current selected swrt_table_resource : l3switch-2
        Current selected swrt_multicast_table : Off
        Current selected unicast multipath number: 4
        Current selected port-channel load-balance-all-port: Off
        IP routing entry :
            Unicast : current number=98 , max number=8093
            Multicast : current number=0 , max number=2048
            ARP : current number=2 , max number=15360
        IPv6 routing entry :
            Unicast : current number=34 , max number=3007
            Multicast : current number=0 , max number=1024
            NDP : current number=2 , max number=15360
        Multipath table entry : current number=0 , max number=512
        MAC-Address table entry : current number=1014 , max number=81920
        VXLAN Layer2 Nexthop entry : current number=0 , max number=0
        System Layer2 Table Mode : mode=0
        Flow detection mode : layer3-mirror-5
          Used resources for filter inbound(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/1024    2/1024
          Used resources for QoS(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/ 512       n/a
          Used resources for UPC(Used/Max)
                    MAC      IPv4      IPv6
                    n/a    0/ 512       n/a
          Used resources for Mirror inbound(Used/Max)
                    MAC      IPv4      IPv6
                 2/ 512    3/ 512    0/ 512
          Used resources for TCP/UDP port detection pattern
            Resources(Used/Max):  1/32
              Destination Port   Used 
                100-200        :       -/  -/mirror
        Flow detection out mode : layer3-2-out
          Used resources for filter outbound(Used/Max)
                    MAC      IPv4      IPv6
                 0/ 256    0/ 256    0/ 256
        Flow action change
            cos                : enable
            arp discard class  : enable
            arp reply cos      : enable
>

運用コマンドshow environmentでファン,電源,温度の状態,累積稼働時間を確認できます。ファンの運転モードはコンフィグレーションコマンドsystem fan modeで設定できます。次の図に例を示します。

図14‒3 装置の環境状態確認
> show environment
Date 20XX/12/10 10:00:00 UTC
Power slot 1 : PS-M(AC)
Power slot 2 : PS-M(AC)
Fan slot     : FAN-M
 
Fan environment
    Power slot 1 : Fan1(1) = active
                   Speed = --------
    Power slot 2 : Fan2(1) = active
                   Speed = --------
    Fan slot     : Fan3(1) = active
                   Fan3(2) = active
                   Fan3(3) = active
                   Fan3(4) = active
                   Speed = normal
    Fan mode     : 1 (silent)
 
Power environment
    Power slot 1 : active
    Power slot 2 : active
 
Temperature environment
    Main  :  30 degrees C
    Warning level : normal
 
Accumulated running time
    Main         :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Power slot 1 :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Power slot 2 :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
    Fan slot     :  total    : 365 days and 18 hours.
                    critical : 10 days and 8 hours.
>

運用コマンドshow environmentのtemperature-loggingパラメータで温度履歴情報を確認できます。次の図に例を示します。

図14‒4 温度履歴情報の確認
> show environment temperature-logging
Date 20XX/12/10 20:00:00 UTC
Date         0:00  6:00 12:00 18:00
20XX/12/10      -     -  26.0  24.0
20XX/12/09   22.2  24.9  26.0  24.0
20XX/12/08   24.0  23.5  26.0  24.0
20XX/12/07   21.0     -  26.0  24.0
20XX/12/06   25.6     -  26.0  24.0
20XX/12/05   21.8  25.1  26.0  24.0
20XX/12/04   24.3  24.2  26.0
>