コンフィグレーションガイド Vol.1


12.1.3 装置の状態確認

運用コマンドshow systemで装置の動作状態や実装メモリ量などを確認できます。次の図に例を示します。

図12‒2 装置の状態確認
> show system
Date 20XX/12/15 06:35:27 UTC
System: AX3640S-24TW, OS-L3A Ver. 11.12
Node : Name=System Name
    Contact=Contact Address
    Locate=Location
    Elapsed time : 2days 03:25:01
    Machine ID : 0012.e268.2c21
    Power redundancy-mode : check is not executed
    Module slot 1 : active PS-M(AC)
        Fan  : active No = Fan1(1) , Fan1(2) Speed = normal
        PS   : active
        Lamp : Power LED=green , ALM1 LED=light off , ALM2 LED=light off
    Module slot 2 : active FAN-M
        Fan  : active No = Fan2(1) , Fan2(2) Speed = normal
        PS   : not power supply module
        Lamp : ALM LED=light off
    Main board : active
        Boot : 20XX/12/13 03:10:15 , power on
        Fatal restart : CPU 0 times, SW 0 times
        Lamp : Power LED=green , Status LED1=green
        Board : CPU=PowerPC 533MHz , Memory=524,304kB(512MB)
        Temperature : normal(27degree)
        Flash :
                  user area   config area     dump area    area total
            used   35,240kB          57kB       2,444kB      37,741kB
            free    2,439kB       7,208kB       5,660kB      15,307kB
            total  37,679kB       7,265kB       8,104kB      53,048kB
        MC : notconnect
    Device resources
        Current selected swrt_table_resource: l3switch-2
        Current selected swrt_multicast_table: On
        Current selected unicast multipath number: 8
        IP routing entry :
            Unicast : current number=5 , max number=8192
            Multicast : current number=5 , max number=256
            ARP : current number=2 , max number=1024
        IPv6 routing entry :
            Unicast : current number=2 , max number=2048
            Multicast : current number=5 , max number=128
            NDP : current number=2 , max number=1024
        Multipath table entry : current number=0 , max number=128
        MAC-Address table entry(Unit1) : current number=2 , max number=32768
        MAC-Address table entry(Unit2) : current number= - , max number= -
        System Layer2 Table Mode : mode=0
        Flow detection mode : layer3-2
          Used resources for filter inbound(Used/Max)
                                     MAC     IPv4     IPv6
            Port 0/ 1- 3       :     n/a   30/256      n/a
            Port 0/ 4- 6       :     n/a   24/256      n/a
            Port 0/ 7- 9       :     n/a   24/256      n/a
            Port 0/10-12       :     n/a   24/256      n/a
            Port 0/13-15       :     n/a   24/256      n/a
            Port 0/16-18       :     n/a   24/256      n/a
            Port 0/19-21       :     n/a   24/256      n/a
            Port 0/22-24       :     n/a    2/256      n/a
            VLAN               :     n/a      n/a      n/a
          Used resources for QoS(Used/Max)
                                     MAC     IPv4     IPv6
            Port 0/ 1- 6       :     n/a   18/128      n/a
            Port 0/ 7-12       :     n/a   10/128      n/a
            Port 0/13-18       :     n/a   10/128      n/a
            Port 0/19-24       :     n/a   10/128      n/a
            VLAN               :     n/a      n/a      n/a
          Used resources for UPC(Used/Max)
                                     MAC     IPv4     IPv6
            Port 0/ 1- 6       :     n/a   20/128      n/a
            Port 0/ 7-12       :     n/a   10/128      n/a
            Port 0/13-18       :     n/a   10/128      n/a
            Port 0/19-24       :     n/a   10/128      n/a
            VLAN               :     n/a      n/a      n/a
          Used resources for TCP/UDP port detection pattern
            Resources(Used/Max):  0/16
        Flow detection out mode : layer3-1-out
          Used resources for filter outbound(Used/Max)
                                     MAC     IPv4     IPv6
            Port 0/ 1- 6       :     n/a   30/128      n/a
            Port 0/ 7-12       :     n/a   24/128      n/a
            Port 0/13-18       :     n/a   24/128      n/a
            Port 0/19-24       :     n/a   24/128      n/a
            VLAN               :     n/a      n/a      n/a
>

運用コマンドshow environmentでファン,電源,温度の状態,累積稼働時間を確認できます。ファンの運転モードはコンフィグレーションコマンドsystem fan modeで設定できます。次の図に例を示します。

図12‒3 装置の環境状態確認
> show environment
Date 20XX/12/10 10:00:00 UTC
Fan environment 
    Fan   : active
    Speed : normal
    Mode  : 2 (cool)
 
Power environment
    PS    : active
    EPU   : active
 
Temperature environment
    Main  :  27 degrees C
    Warning level : normal
 
Accumulated running time
    Main  :  total    : 365 days and 18 hours.
             critical : 202 days and 22 hours.
>

運用コマンドshow environmentのtemperature-loggingパラメータで温度履歴情報を確認できます。次の図に例を示します。

図12‒4 温度履歴情報の確認
> show environment temperature-logging
Date 20XX/12/10 20:00:00 UTC
Date         0:00  6:00 12:00 18:00
20XX/12/10      -     -  26.0  24.0
20XX/12/09   22.2  24.9  26.0  24.0
20XX/12/08   24.0  23.5  26.0  24.0
20XX/12/07   21.0     -  26.0  24.0
20XX/12/06   25.6     -  26.0  24.0
20XX/12/05   21.8  25.1  26.0  24.0
20XX/12/04   24.3  24.2  26.0
>