23.3.6 Checking detailed fault information
Use the show cfm fault detail command to display the status of failure detection and the CCM information. This information is an aid for detecting failures for each failure type. The remote MEP that sent the CCM can be checked in the RMEP, MAC, and VLAN sections.
>show cfm fault detail Date 20XX/03/21 12:23:41 UTC MD:7 MA:1000 MEP:1000 Fault OtherCCM : - RMEP:1020 MAC:0012.e220.1e22 VLAN:1000 Time:20XX/03/20 11:22:17 ErrorCCM : - Timeout : - PortState: - RDI : On RMEP:1011 MAC:0012.e220.11a2 VLAN:1000 Time:20XX/03/21 11:42:10 > |
The remote MEP information displayed by the show cfm fault detail command is an aid in failure detection. In actuality, failures might occur at multiple remote MEPs.
You can use the show cfm remote-mep command to find the remote MEP where a failure is occurring from the ID and Status sections of the displayed remote MEP information.
>show cfm remote-mep Date 20XX/03/21 12:25:30 UTC Total RMEP Counts: 5 Domain Level 7 Name(str): ProviderDomain_7 MA 1000 Name(str) : Tokyo_to_Osaka MEP ID:1000 0/20(Up) Enable Status:RDI RMEP Information Counts: 3 ID:1011 Status:- MAC:0012.e200.005a Time:20XX/03/21 12:25:29 ID:1020 Status:RDI MAC:0012.e220.1e22 Time:20XX/03/21 12:25:29 ID:1030 Status:RDI MAC:0012.e220.1e09 Time:20XX/03/21 12:25:29 MA 2000 Name(str) : Tokyo_to_Nagoya MEP ID:8012 CH1 (Up) Enable Status:- RMEP Information Counts: 2 ID:8003 Status:- MAC:0012.e20a.1241 Time:20XX/03/21 12:25:28 ID:8004 Status:- MAC:0012.e20d.12a1 Time:20XX/03/21 12:25:29 > |