Configuration Guide Vol. 2


23.3.6 Checking detailed fault information

Use the show cfm fault detail command to display the status of failure detection and the CCM information. This information is an aid for detecting failures for each failure type. The remote MEP that sent the CCM can be checked in the RMEP, MAC, and VLAN sections.

Figure 23-37: Result of executing show cfm fault detail command
>show cfm fault detail
Date 20XX/03/21 12:23:41 UTC
MD:7  MA:1000  MEP:1000  Fault
  OtherCCM : -  RMEP:1020 MAC:0012.e220.1e22 VLAN:1000 Time:20XX/03/20 11:22:17
  ErrorCCM : -
  Timeout  : -
  PortState: -
  RDI      : On RMEP:1011 MAC:0012.e220.11a2 VLAN:1000 Time:20XX/03/21 11:42:10
>

The remote MEP information displayed by the show cfm fault detail command is an aid in failure detection. In actuality, failures might occur at multiple remote MEPs.

You can use the show cfm remote-mep command to find the remote MEP where a failure is occurring from the ID and Status sections of the displayed remote MEP information.

Figure 23-38: Result of executing show cfm remote-mep command
>show cfm remote-mep
Date 20XX/03/21 12:25:30 UTC
Total RMEP Counts:      5
Domain Level 7 Name(str): ProviderDomain_7
  MA 1000  Name(str) : Tokyo_to_Osaka
    MEP ID:1000  0/20(Up)    Enable   Status:RDI
      RMEP Information  Counts:  3
      ID:1011  Status:-           MAC:0012.e200.005a  Time:20XX/03/21 12:25:29
      ID:1020  Status:RDI         MAC:0012.e220.1e22  Time:20XX/03/21 12:25:29
      ID:1030  Status:RDI         MAC:0012.e220.1e09  Time:20XX/03/21 12:25:29
  MA 2000  Name(str) : Tokyo_to_Nagoya
    MEP ID:8012  CH1 (Up)    Enable   Status:-
      RMEP Information  Counts:  2
      ID:8003  Status:-           MAC:0012.e20a.1241  Time:20XX/03/21 12:25:28
      ID:8004  Status:-           MAC:0012.e20d.12a1  Time:20XX/03/21 12:25:29
>