Configuration Guide Vol. 2


23.2.1 List of configuration commands

The following tables list CFM configuration commands.

Table 23-14: List of configuration commands

Command name

Description

domain name

Sets the name used for the applicable domain.

ethernet cfm cc alarm-priority

Sets the failure level detected by the CC functionality.

ethernet cfm cc alarm-reset-time

Sets the period of time until the CC functionality recognizes that the failure is a redetected failure.

ethernet cfm cc alarm-start-time

Set the number of seconds between when a failure is detected by CC and when SNMP notification is sent.

ethernet cfm cc enable

Sets in a domain an MA in which the CC functionality is used.

ethernet cfm cc interval

Sets the CCM sending interval.

ethernet cfm domain

Sets a domain.

ethernet cfm enable (global)

Starts CFM.

ethernet cfm enable (interface)

Stops CFM when no ethernet cfm enable is set.

ethernet cfm mep

Sets a MEP used by the CFM functionality.

ethernet cfm mip

Sets a MIP used by the CFM functionality.

ma name

Sets the name of an MA to be used in the applicable domain.

ma vlan-group

Sets the VLAN belonging to the MA used in the applicable domain.