23.2.1 List of configuration commands
The following tables list CFM configuration commands.
Command name |
Description |
---|---|
domain name |
Sets the name used for the applicable domain. |
ethernet cfm cc alarm-priority |
Sets the failure level detected by the CC functionality. |
ethernet cfm cc alarm-reset-time |
Sets the period of time until the CC functionality recognizes that the failure is a redetected failure. |
ethernet cfm cc alarm-start-time |
Set the number of seconds between when a failure is detected by CC and when SNMP notification is sent. |
ethernet cfm cc enable |
Sets in a domain an MA in which the CC functionality is used. |
ethernet cfm cc interval |
Sets the CCM sending interval. |
ethernet cfm domain |
Sets a domain. |
ethernet cfm enable (global) |
Starts CFM. |
ethernet cfm enable (interface) |
Stops CFM when no ethernet cfm enable is set. |
ethernet cfm mep |
Sets a MEP used by the CFM functionality. |
ethernet cfm mip |
Sets a MIP used by the CFM functionality. |
ma name |
Sets the name of an MA to be used in the applicable domain. |
ma vlan-group |
Sets the VLAN belonging to the MA used in the applicable domain. |