Configuration Guide Vol. 2


16.2.1 List of configuration commands

The following table lists the commands used to configure uplink redundancy.

Table 16-4: List of configuration commands

Command name

Description

switchport backup flush-request transmit

Enables the sending of flush control frames to upstream switches at switchover or switch-back to request that the upstream switches clear their MAC address tables.

switchport backup interface

Allows you to specify a primary port and secondary port for uplink redundancy and define them as an uplink port pair. You can also specify the automatic switch-back wait time to enable automatic switch-back.

switchport backup mac-address-table update exclude-vlan

Specifies a VLAN as one to which MAC address update frames are not to be sent.

switchport backup mac-address-table update transmit

Enables the sending of MAC address update frames to upstream switches at switchover or switch-back to request that the upstream switches update their MAC address tables.

switchport backup reset-flush-port

Enables the port reset function at switching and switchback.

switchport backup reset-flush-time

Sets the port down time by the port reset function.

switchport-backup startup-active-port-selection

Enables the functionality to fix the active port at Switch startup.