Message and Log Reference


2.12 ULR

This section describes the operation messages for the event location ULR.

Table 2-25: Operation messages for event location ULR

Message

ID

Event

Level

Message text

Content and response

20a00001

E4

ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(<switch no.>/<nif no.>/<port no.>).

The active port was switched to the secondary port because an error occurred in the primary port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Check the failure in the primary port.

20a00002

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>).

The active port was switched to the primary port because an error occurred in the secondary port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Check the failure in the secondary port.

20a00003

E4

ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(ChGr:<channel group number>).

The active port was switched to the secondary port because an error occurred in the primary port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

Check the failure in the primary port.

20a00004

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>).

The active port was switched to the primary port because an error occurred in the secondary port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

Check the failure in the secondary port.

20a00005

E4

ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(<switch no.>/<nif no.>/<port no.>).

The active port was switched to the secondary port because an error occurred in the primary port.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Check the failure in the primary port.

20a00006

E4

ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>).

The active port was switched to the primary port because an error occurred in the secondary port.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Check the failure in the secondary port.

20a00007

E4

ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(ChGr:<channel group number>).

The active port was switched to the secondary port because an error occurred in the primary port.

<channel group number>: Channel group number

[Action]

Check the failure in the primary port.

20a00008

E4

ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(ChGr:<channel group number>).

The active port was switched to the primary port because an error occurred in the secondary port.

<channel group number>: Channel group number

[Action]

Check the failure in the secondary port.

20a00009

E4

ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(<switch no.>/<nif no.>/<port no.>), because command execution.

The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00010

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>), because command execution.

The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00011

E4

ULR:Active port is switched to secondary port(<switch no.>/<nif no.>/<port no.>) from primary port(ChGr:<channel group number>), because command execution.

The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

None.

20a00012

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>), because command execution.

The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

None.

20a00013

E4

ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(<switch no.>/<nif no.>/<port no.>), because command execution.

The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00014

E4

ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>), because command execution.

The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00015

E4

ULR:Active port is switched to secondary port(ChGr:<channel group number>) from primary port(ChGr:<channel group number>), because command execution.

The active port was switched from the primary port to the secondary port because the set switchport-backup active command was executed.

<channel group number>: Channel group number

[Action]

None.

20a00016

E4

ULR:Active port is switched to primary port (ChGr:<channel group number>) from secondary port (ChGr:<channel group number>), because command execution.

The active port was switched back from the secondary port to the primary port because the set switchport-backup active command was executed.

<channel group number>: Channel group number

[Action]

None.

20a00017

E4

ULR:Primary port(<switch no.>/<nif no.>/<port no.>) became the active port.

The primary port has become the active port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00018

E4

ULR:Primary port(ChGr:<channel group number>), became the active port.

The primary port has become the active port.

<channel group number>: Channel group number

[Action]

None.

20a00019

E4

ULR:Secondary port(<switch no.>/<nif no.>/<port no.>) became the active port.

The secondary port has become the active port.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00020

E4

ULR:Secondary port(ChGr:<channel group number>) became the active port.

The secondary port has become the active port.

<channel group number>: Channel group number

[Action]

None.

20a00021

E4

ULR:Both uplink redundant port(<switch no.>/<nif no.>/<port no.>) and port(<switch no.>/<nif no.>/<port no.>) are down.

Both the primary port and the secondary port have gone down.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Make sure that no error occurred between the primary and secondary port.

20a00022

E4

ULR:Both uplink redundant port(<switch no.>/<nif no.>/<port no.>) and port(ChGr:<channel group number>) are down.

Both the primary port and the secondary port have gone down.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

Make sure that no error occurred between the primary and secondary port.

20a00023

E4

ULR:Both uplink redundant port(ChGr:<channel group number>) and port(<switch no.>/<nif no.>/<port no.>) are down.

Both the primary port and the secondary port have gone down.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

Make sure that no error occurred between the primary and secondary port.

20a00024

E4

ULR:Both uplink redundant port(ChGr:<channel group number>) and port(ChGr:<channel group number>) are down.

Both the primary port and the secondary port have gone down.

<channel group number>: Channel group number

[Action]

Make sure that no error occurred between the primary and secondary port.

20a00025

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(<switch no.>/<nif no.>/<port no.>), because preemption execution.

The active port was switched from the secondary port to the primary port because automatic preemption was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00026

E4

ULR:Active port is switched to primary port(<switch no.>/<nif no.>/<port no.>) from secondary port(ChGr:<channel group number>), because preemption execution.

The active port was switched from the secondary port to the primary port because automatic preemption was executed.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

<channel group number>: Channel group number

[Action]

None.

20a00027

E4

ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(<switch no.>/<nif no.>/<port no.>), because preemption execution.

The active port was switched from the secondary port to the primary port because automatic preemption was executed.

<channel group number>: Channel group number

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00028

E4

ULR:Active port is switched to primary port(ChGr:<channel group number>) from secondary port(ChGr:<channel group number>), because preemption execution.

The active port was switched from the secondary port to the primary port because automatic preemption was executed.

<channel group number>: Channel group number

[Action]

None.

20a00029

E4

ULR:Exceeded the number of MAC Address Table entry update request to uplink-switch from active port(<switch no.>/<nif no.>/<port no.>).

The number of MAC address table entry update requests from an uplink port of the Switch to an upstream uplink switch exceeded the limit.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00030

E4

ULR:Exceeded the number of MAC Address Table entry update request to uplink-switch from active port(ChGr:<channel group number>).

The number of MAC address table entry update requests from an uplink port of the Switch to an upstream uplink switch exceeded the limit.

<channel group number>: Channel group number

[Action]

None.

20a00031

E4

ULR:Port(<switch no.>/<nif no.>/<port no.>) inactivated because of 'reset-flush-port'.

The port is placed in inactive status by the port reset function.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00032

E4

ULR:ChGr(<channel group number>) inactivated because of 'reset-flush-port'.

The port is placed in inactive status by the port reset function.

<channel group number>: Channel group number

[Action]

None.

20a00033

E4

ULR:Port(<switch no.>/<nif no.>/<port no.>) activated because of 'reset-flush-port'.

The port is released from inactive status by the port reset function.

<switch no.>/<nif no.>/<port no.>: Switch number/NIF number/port number

[Action]

None.

20a00034

E4

ULR:ChGr(<channel group number>) activated because of 'reset-flush-port'.

The port is released from inactive status by the port reset function.

<channel group number>: Channel group number

[Action]

None.