Message and Log Reference


1.2.4 Event level

Events are divided into seven levels according to severity. The table below describes the event levels and their contents.

Table 1-7: Event levels and contents

Event level

Displayed information

Description

9

E9

Indicates a fatal failure.

The entire switch stops, either restarting the switch or stopping operation.

8

E8

Indicates a serious failure.

If a fan, power supply, or part of a unit fails, and the fault is a hardware partial failure, restart or stop the hardware.

R8

Indicates severe disaster recovery.

7

E7

Indicates a software partial failure.

Or indicates abnormal temperature of equipment without equipment stop.

R7

Indicates software partial failure recovery.

6

E6

Not used

R6

Not used

5

E5

Not used

R5

Not used

4

E4

Shows information about network failure detection and lines.

3

E3

Warning

The following table shows the correspondence between message types and event levels.

Table 1-8: Correspondence between message types and event levels

Message type

Event level

ERR

E9~E5

EVT

E4, E3, R8~R5